3. Operating Instructions

3-1 Control System Chart

Operation Mode
Main switch operation
Remote control operation
Operation selector mode
Cooling operation
Fan operstion
Heating operstion
Fan speed selector mode
Manual 3-step
A i rflow selector mode
Left/Right turn
UP/Down Turn
R e s e rvation operation
m o d e
Convenience function
Brief reservation
Samsung Electronics
Operation/stop, operation selection, blow volme selection, turbo, temperature
control
Start/stop, operation selection, fan speed selection, turbo, temperature con-
trol, reservation operation, sleeping operation, left/light turning, up/down
turning, turbo/remote
Cooling and heating control according to the set temperature
Auto
Room temperture≥21°C±2°C(remocon input)=cooling operation
Desired temperature=24°C±2°C
Room temperature<21°C±2°C(remocon input)=heating operation
Desired temperature=22°C±2°C
Indoor temperature control according to the set temperature.
Indoor temperature control accoding to the set temperature(18°C<->30°C)
Dry operation
Decide the dry cydle by the difference in room temperature(18°C-30°C)
Operation of the indoor fan moter only(High, midium, low)
Indoor temperature control according to the set temperature(16°C<->30°C)
APH180HD/180ED=(0), APH180CD=(X)
High, Medium, Low(slectable at the cool and fan mode)
The hige, midium, low wind is automaticallly changed by CHAOS calculation.
Natural
In automatically operating, it is fixed with natural wind.
The automatic fan control according to the difference between the indoor and
Auto
the set temperatures.
Selectable only by the remote control and turn and turn/stop are possible only.
Selectable only by the remote control and turn and turn/stop are possible only.
Start time
Selectable only by the remote control and the time of operation ON is set..
reservation
Stop time
Selectable only by the remote control and the time of operation OFF is set..
reservation
Selectable only by eremote control and the off reservation function is performed
after 30 minutes, 1,2,3 and 5 hours.
3-1