Electrical Adjustment - Sanyo VPC-X1220EX Service Manual

Hide thumbs Also See for VPC-X1220EX:
Table of Contents

Advertisement

3. ELECTRICAL ADJUSTMENT

3-1. Table for Servicing Tools
Ref. No.
Name
J-1
Pattern box
J-2
Calibration software
J-3
Chroma meter
J-4
Spare lump (pattern box)
J-5
Discharge jig
J-6
Collimator
Spare lump (collimator)
J-7
Download the calibration software and the firmware
from the following URL.
http://www.overseas.sanyo.com/dcamera service/
Place the DscCalDi.exe file, camapi32.dll file and
QrCodeInfo.dll file together into a folder of your
choice.
J-1
J-4
3-2. Equipment
1. PC (IBM R -compatible PC, Windows 2000 or XP or Vista)
3-3. Adjustment Items and Order
1. Lens Adjustment (Infinity)
2. AWB Adjustment
3. CCD White Point Defect Detect Adjustment
4. CCD Black Point And White Point Defect Detect Adjust-
ment In Lighted
Note: If the lens, board and changing the part, it is necessary
to adjust again. Item 1-4 adjustments should be carried out in
sequence.
Part code
Number
VJ8-0190
1
1
1
VJ8-0192
1
VJ8-0191
1
VJ8-0188
1
VJ8-0260
1
VJ8-0282
J-3
J-5
3-4. Setup
1. System requirements
Windows 2000 or XP or Vista
IBM R -compatible PC with pentium processor
USB port
40 MB RAM
Hard disk drive with at least 15 MB available
VGA or SVGA monitor with at least 256-color display
2. Pattern box
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure. It is used after adjusting the
chroma meter (VJ8-0192) adjust color temperature to 3100 ±
20 K and luminosity to 900 ± 20 cd/m
the lump and its circumference are high temperature during
use and after power off for a while.
3. Computer screen during adjustment
Calibration
Upload
AWB
Firmware
Focus
Data
UV Matrix
Cal Mode
PAF Cal.
OK
EVF
Cal Data
LCD Type
OK
USB storage
Get
VID
Set
PID
Backrush pulse :
Get
3-5. Connecting the camera to the computer
This camera requires a DC adaptor (sold separately) in order
to use an AC adaptor.
1. Insert the DC adaptor to the camera.
2. Insert the AC adaptor's cable to DC terminal of the DC
adaptor.
3. Line up the arrow on the cable connector with the notch on
the camera's USB port. Insert the connector.
4. Locate a USB port on your computer.
5. If "USB CONNECTION" is displayed, choose the "COM
PUTER", and press the SET button.
Next, choose the "CARD READER", and press the SET
button.
– 14 –
2
. Be careful of handling
LCD
R Bright
B Bright
RGB Offset
Gain
Tint
Phase
VCO
H AFC
Test
Set
Serial
Set
Set
Rev.
Set
Set
VCOMDC
VCOMPP
Hall Cal.
Setting
Language
Video Mode
Factory Code

Advertisement