Urban BFX770 Operating Instructions Manual page 6

Terrace & patio heater
Table of Contents

Advertisement

STEP-BY-STEP PROCEDURE
STEP 1:
Wheel Fitting
If fitting wheel assembly please refer to page 10
first and fit before positioning the post brackets.
1-1 Place the 3 piece post bracket on each
position of the cylinder base as shown.
1-2 Screw in the 3 pieces of M8 x 15mm bolts
on the bracket cylinder assembly.
1-3 Tighten each of the bolts.
STEP 2 :
2-1 Put the post on top of the 3 piece
post bracket assembly as shown.
2-2 Screw in the 6 pieces of M6 x 35mm
bolts and M6 nuts through each post hole.
2-3 Tighten each bolt.
STEP 3 :
3-1 Put the cylinder housing through the
post as shown.
6
CAUTION & LEAKAGE TEST
PRECAUTIONS
 Periodically check the whole gas system for leaks or
immediately if the smell of gas is detected.
 Extinguish all open flames.
 Never leak test while smoking.
 If you cannot stop a leak, turn off the gas supply and
call your gas supplier.
 The heater must be checked with a full cylinder.
 Do not use the heater until all connections have passed
a leak test.
 Only use parts recommended. Substitute parts can void
the warranty.
PROCEDURE FOR A LEAKAGE TEST
Gas connections on the appliance are leak tested at the factory prior
to shipment. A complete gas tightness check must be carried out at
the installation site.
• Make a soapy solution of one part liquid detergent and one part
water. The soapy solution can be applied with a spray bottle,
brush or rag. Soap bubbles will appear where a leak is present.
• Make sure the safety control value is in the OFF position.
• Turn the gas supply ON.
• If a leak is present, turn off the gas supply. Tighten any leaking
fittings, then turn on gas supply and re-check.
11

Advertisement

Table of Contents
loading

Table of Contents