Vent Sensor - Samsung DV405 Series User Manual

Gas and electric dryer
Hide thumbs Also See for DV405 Series:
Table of Contents

Advertisement

operating Instructions, tips

VENT SENSOR

Your Samsung dryer is equipped with a Vent Sensor, which detects and notifi es you when it is time to clean
the ductwork. Keep your dryer safe and effi cient by cleaning the ducts when prompted.
The Vent Sensor detects any duct blockages
You can fi gure out whether there is a duct blockage from the "Vent Sensor
digital display.
Level
0
1
2
In the LEVEL 2 state, this lamp blinks for 3 hours after the completion of the cycle. (If the wrinkle
prevention function is activated, this message is displayed for up to 3 hours.)
If the power button is pressed or the door is opened, the power is immediately turned off .
For more information about the duct installation, please refer to the "" section on page 9.
• Although the dryer is available even if the blockage message is displayed, the drying time
may be extended.
• If the LEVEL 1 message is displayed the fi rst time the dryer is run after the installation,
check the connection and clean the duct. If the LEVEL 1 message appears even
after you have checked and cleaned the ducts, this may indicate that there are some
restrictions of the duct due to the length, condition, etc.
If this occurs, you can use the dryer normally and no countermeasures need to be taken.
However, the drying time may be extended or the drying performance may be degraded.
28_ operating Instructions, tips
DV405ETPAWR-03021F-06_EN.indd Sec13:28
DV405ETPAWR-03021F-06_EN.indd Sec13:28
Message
The ductwork is free from
The "Vent Sensor
"
blockages.
lamp is turned off .
When a part of the duct
The "Vent Sensor
"
or the lint fi lter is blocked
lamp illuminates.
by lint or a foreign object.
When the resistance is
high because the duct is
too long or bent.
When the duct is blocked
The "Vent Sensor
"
by lint or a foreign object.
lamp blinks.
When the resistance is
very high because the
duct is too long or bent
excessively.
" lamp of the
Status
Solution
-
Check the duct
connection and shorten
the duct and straighten it
if necessary.
Check the lint fi lter or
the duct and clean it if
necessary.
Check the duct
connection and shorten
the duct and straighten it
if necessary.
Check the lint fi lter or the
duct and clean it as soon
as possible.