Marlo Incorporated CMP series Installation, Operation And Maintenance Manual

Metered series automatic water conditioner

Advertisement

"CMP" & "C" Series
Metered Series
AUTOMATIC WATER
CONDITIONERS
INSTALLATION, OPERATION, AND
MAINTENANCE MANUAL
FILL IN FOR FUTURE REFERENCE
MODEL NO:___________________________________________
SERIAL NO:___________________________________________
DATE INSTALLED:_____________________________________ _
DEALER:__________________________________ ____________
8-171 R5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMP series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Marlo Incorporated CMP series

  • Page 1 “CMP” & “C” Series Metered Series AUTOMATIC WATER CONDITIONERS INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FILL IN FOR FUTURE REFERENCE MODEL NO:___________________________________________ SERIAL NO:___________________________________________ DATE INSTALLED:_____________________________________ _ DEALER:__________________________________ ____________ 8-171 R5...
  • Page 2: Specification Table

    “CMP” & “C” Series Automatic Water Conditioners ( “CMP” SERIES ) SPECIFICATION TABLE Model Number Units CMP-22K CMP-30K CMP-40K CMP-45K CMP-60K CMP-22-C CMP-30-C 22,836 30,448 38,060 45,672 60,896 22,836 30,448 Exchange Capacity 19,509 26,012 32,515 39,018 52,024 19,509 26,012 Kilograms 14,514 19,352 24,190...
  • Page 3 “CMP” & “C” Series Automatic Water Conditioners 8-171 R5...
  • Page 4: Installation Fitting Assemblies

    “CMP” & “C” Series Automatic Water Conditioners Installation Fitting Assemblies Installation fittings connect to the control valve or the bypass valve using nuts that only require hand tightening. Hand tight nut connections between control valve and installation fittings, control valve and bypass valve, and bypass valve and installation fittings allow for ease serviceability.
  • Page 5 “CMP” & “C” Series Automatic Water Conditioners GENERAL Shut off all water at main supply valve. Shut off the fuel supply to water heater. Open faucets (hot and cold) nearest pump or water meter to relieve pressure and drain system. Move softener into the installation position.
  • Page 6 “CMP” & “C” Series Automatic Water Conditioners PRESSURE TEST THE INSTALLATION The plumbing system can now be checked for any possible leaks Put the unit into backwash. To do this, push and hold the REGEN button for 3-5 seconds. When the Valve stops cycling, unplug the unit.
  • Page 7: Control Valve Function And Cycles Of Operation

    “CMP” & “C” Series Automatic Water Conditioners Control Valve Function and Cycles of Operation This glass filled Noryl fully automatic control valve is designed as the primary control center to direct and regulate all cycles of a water softener or filter. When the control valve is set up as a softener, the control valve can be set to perform down flow or up flow regeneration with the proper piston.
  • Page 8: Installer Displays/Settings

    “CMP” & “C” Series Automatic Water Conditioners Installer Displays/Settings STEP 1 - Press NEXT and simultaneously for 3 seconds. STEP 2 - Hardness: Set the amount of hardness in grains of hardness as Step 1 calcium carbonate per gallon using the buttons.
  • Page 9 “CMP” & “C” Series Automatic Water Conditioners Regeneration Mode 2 8 : 2 2 REGEN Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
  • Page 10: Flow Diagrams

    “CMP” & “C” Series Automatic Water Conditioners FLOW DIAGRAMS flow diagram...service flow diagram...backwash TO DRAIN PISTON ROD IS PISTON ROD IS BOTTOMED BELOW 2nd STEP DOWN OUT IN “HOME” POSITION SUPPLY SUPPLY WATER WATER OUTLET PORT FOR OUTLET PORT FOR SERVICE WATER SERVICE WATER SUPPLY WATER...
  • Page 11: Bypass Valve

    “CMP” & “C” Series Automatic Water Conditioners Bypass Valve The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to per- form control valve repairs or maintenance. The WS1 bypass valve is particularly unique in the water treatment industry due to its versatility and state of the art design features.
  • Page 12: Parts Listing

    “CMP” & “C” Series Automatic Water Conditioners “C” Series Valve (Metered Shown) Media Tank Brine Media Tank Jacket Valve w/ Cover Brine Tank Cover Assembly Media Distributor Tube Brine Line Hosing w/ Screen Brine Well Caps Brine Well Brine Brine Valve Safety Valve Brine Tank Safety...
  • Page 13 “CMP” & “C” Series Automatic Water Conditioners “C” Series Lo Pro Cover Salt Port Cover Valve (Does not include Bypass) Brine Valve Assembly Brine Line Hose Brine Cabinet Valve Safety Drain Line Elbow Brine Well Overflow Elbow Cover Brine Well Brine Float Media Media Tank...
  • Page 14 8-171 R5...
  • Page 15: Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston And Spacer Stack Assembly

    “CMP” & “C” Series Automatic Water Conditioners Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston and Spacer Stack Assembly Item No. Part No. Description Quantity A2466034 *Spacer Stack Assembly w/o o-rings A2080077 Drive Cap Assembly use item 16 O-Ring 228 (use Valve O-ring Kit) A2309040 Piston Downflow Assembly...
  • Page 16 “CMP” & “C” Series Automatic Water Conditioners Injector Cap, Injector Screen, Injector, Plug , O-Ring, Refill and Refill Port Plug, &Drain Line - 3/4” t Part of Kit, O-ring (Item #51, pg. 20) 25a, 25b Proper flow washer orientation directs water flow towards the washer face with rounded edge.
  • Page 17: Injector Cap, Injector Screen, Injector, Plug And O-Ring

    “CMP” & “C” Series Automatic Water Conditioners Injector Cap, Injector Screen, Injector, Plug and O-Ring Item No. Part No. Description Quantity A2080079 Injector Cap Use Item 51 O-Ring 135 (Use Valve O-ring Kit) A2142016 Injector Screen A2079059 Injector Assembly Z Plug See note A2079060 Injector Assembly A Black...
  • Page 18: Drain Line

    “CMP” & “C” Series Automatic Water Conditioners Drain Line - 1” Drawing No. Order No. Description Quantity A2411015 Elbow Locking Clip A2099072 Drain FTG 1” Straight A2005075 Drain FTG Body 1” A2097040 Drain FTGAdapter 1” A2077179 O-Ring 019 A2453012 Split Ring A2095069 Nut 1”...
  • Page 19: Water Meter And Meter Plug

    “CMP” & “C” Series Automatic Water Conditioners Water Meter and Meter Plug Item No. Part No. Description Quantity A2095069 Nut 1” Quick Connect A2360039 Meter Assembly A2100027 Turbine Assembly use item 51 O-Ring 215 (Use Valve O-ring Kit) A2287077 Meter Plug Assembly (Time clock option) *Item #37 includes Items #38 &...
  • Page 20 “CMP” & “C” Series Automatic Water Conditioners Item No. Part No. Description Quantity A2095069 Nut 1” Quick Connect A2453012 Split Ring use item 52 O-Ring 215 (Kit available - see Item #10) A2607004 Bypass 1” Rotor A2080090 Bypass Cap A2395009 Bypass Handle A2104036 Bypass Rotor Seal Retainer...
  • Page 21 “CMP” & “C” Series Automatic Water Conditioners (Optional) (Optional) Order No: A2129080 Order No: A2099054 Description: Fitting 1” PVC Male NPT Elbow Assembly Description: Fitting 3/4” & 1” PVC Solvent 90 Drawing No. Order No. Description Quantity Drawing No. Order No. Description Quantity A2095069 Nut 1”...
  • Page 22 “CMP” & “C” Series Automatic Water Conditioners Table 15 Troubleshooting Procedures Problem Possible Cause Solution a. Connect power a. Transformer unplugged 1. Timer does not display b. No electric power at outlet b. Repair outlet or use working outlet time of day c.
  • Page 23 “CMP” & “C” Series Automatic Water Conditioners Troubleshooting Procedures (continued) Problem Possible Cause Solution a. Motor not operating a. Replace motor b. No electric power at outlet b. Repair outlet or use working outlet c. Defective transformer c. Replace transformer 6.
  • Page 24 NOTES 2227 South Street P.O. Box 044170 Racine, WI 53404-7003 Ph. (262) 681-1300 Fax (262) 681-1318 www.Marlo-Inc.com 8-171 R5...

This manual is also suitable for:

C series

Table of Contents

Save PDF