³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV Step 1 Installer Displays/Settings NEXT REGEN CLOCK STEP 1 - Press NEXT and simultaneously for 3 seconds. STEP 2 - Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the buttons.
Page 11
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV Regeneration Mode 2 8 : 2 2 REGEN Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV FLOW DIAGRAMS fl ow diagram...service fl ow diagram...backwash TO DRAIN PISTON ROD IS PISTON ROD IS BOTTOMED BELOW 2nd STEP DOWN OUT IN “HOME” POSITION SUPPLY SUPPLY WATER WATER OUTLET PORT FOR OUTLET PORT FOR SERVICE WATER SERVICE WATER SUPPLY WATER...
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV Bypass Valve The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The WS1 bypass valve is particularly unique in the water treatment industry due to its versatility and state of the art design features.
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV “C” Series Valve (Metered Shown) Media Tank Brine Media Tank Jacket Valve w/ Cover Brine Tank Cover Assembly Media Turbulator Brine Line Hosing Brine Well Caps Brine Well Brine Brine Valve Safety Valve Safety Brine Tank Overflow Drain Brine Float Brine Tube...
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV Water Meter and Meter Plug Item No. Part No. Description Quantity A2095069 Nut 1” Quick Connect A2360039 Meter Assembly A2100027 Turbine Assembly A2077178 O-Ring 215 (Use Valve O-ring Kit) A2287077 Meter Plug Assembly (Time clock option) *Item #37 includes Items #38 &...
Page 20
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV Item No. Part No. Description Quantity A2095069 Nut 1” Quick Connect A2453012 Split Ring A2077178 O-Ring 215 (Kit available - see Item #10) A2607004 Bypass 1” Rotor A2080090 Bypass Cap A2395009 Bypass Handle A2104036 Bypass Rotor Seal Retainer A2077182 O-Ring 135 (use Bypass Valve Kit) A2077223...
Page 21
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV (Standard) (Optional) Order No: A2129080 Order No: A2099054 Description: Fitting 1” PVC Male NPT Elbow Assembly Description: Fitting 3/4” & 1” PVC Solvent 90 Drawing No. Order No. Description Quantity Drawing No. Order No. Description Quantity A2095069 Nut 1”...
Page 22
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV Table 15 Troubleshooting Procedures Problem Possible Cause Solution a. Transformer unplugged a. Connect power 1. Timer does not display b. Repair outlet or use working outlet b. No electric power at outlet time of day c.
Page 23
³&03 &20%2´ 6HULHV :DWHU &RQGLWLRQHUV Troubleshooting Procedures (continued) Problem Possible Cause Solution a. Motor not operating a. Replace motor b. No electric power at outlet b. Repair outlet or use working outlet c. Defective transformer c. Replace transformer 6. Control valve stalled in d.