4.3.2. Command List for Remote Device

To change the configuration for a remote device via over-the-air, firstly you have to use a
command "O" at the local device. The following are a procedure for changing configuration of
remote device via over-the-air.
Configure a remote device at the local device.
Save changes at the local device.
Make a connection between the local device and remote device (Automatically).
Send changes from the local device to the remote device (Automatically).
Apply changes at the remote device and reboot (Automatically).
Item
Syntax
1.
Connecting
AAddr<Enter>
address
2. Baud rate
BBaud Rate
3. COM port
CCOM Port
4. PIN code
EPIN<Enter>
5. Flow control
FFlow Control
6.
Connection
MMode
mode
7. Friendly name
NName<Enter> Set a friendly name up to 11
8. Parity Bit
PParity
9. Stop Bit
SStop
10 View
V
11. Exit
X
12. Usage
?
Remarks1: To configure a remote device via over-the-air, a local device must be able to make a
connection to the remote device.
Remarks2: You can change a PIN code for the remote and local device as follows:
Change a PIN for remote at the local -> Apply it. -> Change a PIN for local and apply it.
Remarks3: Once you change a connecting address, and connection mode for the remote, the
local device won't be able to make a connection to the remote device.
Description
Set a connecting address for
remote device.
Change the baud rate for the
remote.
This is only valid in mode 2.
Authentication Off: Type <Enter>
Authentication On: Type up to 11
characters
Set the Flow control for remote.
Set a connection mode for
remote.
characters for remote.
Set the parity bit.
Set the stop bit.
Display
information for remote
Save changes and return to
main menu.
Print the usage.
UK / Europe Office
Tel: +44 (0)8700 434040
Fax: +44 (0)8700 434045
info@omniinstruments.co.uk
www.omniinstruments.co.uk
Remarks
Paired adapters should
have a same PIN code.
0: None, 1: Odd 2: Even
0: 1 Stop, 1: 2 Stop
configuration
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au
www.omniinstruments.com.au
10
USA / Canada Office
Tel +1-866-849-3441
Fax +1-866-628-8055
info@omniinstruments.net
www.omniinstruments.net

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents