Indoor Unit Control; Cool Operation - Mitsubishi Electric PKH18FK Technical & Service Manual

Split-type,heat pump air conditioners series pkh wall mounted
Hide thumbs Also See for PKH18FK:
Table of Contents

Advertisement

2. INDOOR UNIT CONTROL

2-1 COOL operation

-CENTRALLY CONTROLLED-
POWER
STAND BY
ON
DEFROST
CHECK DRY
HEAT
AUTO
HEAT
COOL
CHECK
SET
WARMER
SET TEMP
F
TEMPERATURE
TIMER OFF
TIMER
MODE
AUTO STOP
HR
AUTO START
FAN SPEED LOW/HIOGH
LOW HIGH
AIR
UP/DOWN
DISCHARGE
F
AUTO RETURN
CHECK
CHECK TEST RUN
MITSUBISHI ELECTRIC
<COOL operation time chart>
Thermostat
Indoor fan
Auto vane
Booster heater
Compressor
w1 Even if the room temperature displayed on remote controller rises above the set temperature during this period, the compressor will not start until this period
has ended.
ON/OFF
COOL/DRY
COOLER
HOURS
SWING
STOP
TEST RUN
Operation starts by
P O W E R b u t t o n
ON.
ON
OFF
LOW or HIGH
ON
OFF
Initally 10 degrees
(Changeable by remote controller setting)
CLOSE
ON
OFF
OFF
ON
OFF
<How to operate>
1 Press POWER ON/OFF button.
2 Press COOL / DRY button to set operation mode to Cool.
NOTE : "Cool" and "DRY" are alternately displayed each time
COOL / DRY button is pressed.
3 To set desired temperature, press WARMER or COOLER
button.
NOTE : Set temperature changes by 2˚F in the range 66~86˚F,
each time WARMER or COOLER button is pressed.
The room temperature
The room temperature
displayed on Remote
displayed on Remote
controller becomes equal
controller rises
to set temperature.
set temperature.
W
Minimum 3 minutes
1
Operation stops by
P O W E R b u t t o n
above
OFF.
LOW or HIGH
CLOSE
31