Optional Parts; Refrigerant Pipes - Mitsubishi Electric PKH18FK Technical & Service Manual

Split-type,heat pump air conditioners series pkh wall mounted
Hide thumbs Also See for PKH18FK:
Table of Contents

Advertisement

OPTIONAL PARTS

13

1. REFRIGERANT PIPES

FOR model: PKH18/24FK
Part No
Pipe length
Pipe size OD
Connection method
FOR model : PKH30/36FK
Part No
Pipe length
Pipe size OD
Connection method
Note 1. How to connect refrigerant pipes.
Factory supplied optional refrigerant pipings contain refrigerant at the above atmospheric pressures. As long as the
connection takes no more than 5 minutes, no air will enter, and there will be no need for air purging. Remove the blind
caps and make the connections within 5 minutes. After the connections for the indoor and outdoor units are made,
open the stop valve on the outdoor unit to allow refrigerant gas to flow.
If piping length exceeds 5m,an additional charge of refrigerant is needed.
Note 2. The following main parts are contained in the optional refrigerant piping kit.
Heat insulating cover, vinyl tapes, nipples, sleeve and flange (for wall hole),connecting cables.
2. TIMER
When using a program timer, PAC-SK65PT, a program timer adapter (PAC-825AD) is also needed.
Part No.
Model Name
2-1 Program timer specifications
Part name
Part No.
Exterior dimensions
Installation
Type of clock
Clock accuracy
Display — Time
— Week
— Timer setting
Program cycle
Timer setting unit
No. of set points
Power rating
Se back function
2-2 Feature of program timer
(1) Daily timer function
Daily timer can be set in 30 minutes units for up to 24 hours.
Each unit can be set for unit ON, unit OFF, or setback operation.
(2) Setback operation (PAC-SK65PT)
Set back operation is useful for reducing running costs
e.g. At a hotel with a 24-hour system
8:00~23:00 Cooling operation with set temperature at 26°C
23:00~8:00 Setback operation with 2 degrees of setback
As shown in the chart on the right, the set temperature rises 2 degrees
automatically during the setback operation. When the setback operation
ends, nomal operation will begin.
(3) Weekly timer function
Daily timer function can apply to each day of the week.
PAC-05FFS-E
5m
PAC-SC51PI-E
5m
PAC-SK65PT (with set back function)
Program timer
Program timer
PAC-SK65PT
o
o
120
120
15mm
Wall mount
Quartz
± 50s / month
Liquid cystal display
Liquid cystal display
Liquid cystal display
24 hours
30 minutes
48 / day
5V DC
Provided
PAC-07FFS-E
PAC-10FFS-E
7m
Liquid : 3/8
Gas : 5/8
Indoor unit : Flared Outdoor unit : Flared
PAC-SC52PI-E
PAC-SC53PI-E
7m
Liquid : 1/2
Gas : 3/4
Indoor unit : Flared Outdoor unit : Flared
˚
28
C
˚
26
C
PAC-15FFS-E
10m
PAC-SC54PI-E
10m
8:00
23:00
Normal
Setback
Normal
operation
operation
operation
15m
15m
8:00
83