Roland V-Cymbal CY-15R Owner's Manual page 10

Drum cymbals roland v-cymbal cy-15r/cy-14c/cy-12h
Hide thumbs Also See for V-Cymbal CY-15R:
Table of Contents

Advertisement

Trigger Parameter Settings for the Sound Module
You may need to adjust the value since these are just the
reference value.
TD-10
(TDW-1 with V-Cymbal Control)
CY-12H
Trigger Type
HH
7
Sensitivity
Threshold
2
Curve
Linear
* Trigger parameters of TRIGGER BANK 2 at the factory defaults are
set for using the V-Cymbals.
* TDW-1 with V-Cymbal Control provides trigger types exclusively for
the V-Cymbals. Advanced Trigger Parameters (e.g. Scan Time) are set
automatically when you set the trigger type.
* When using the CY-15R's three way triggering, refer to p. 9.
TD-10
(TDW-1 Original Version)
CY-12H
P7B
Trigger Type
Sensitivity
7
Threshold
2
Curve
Linear
Scan Time
1.0
Retrigger Cancel
8
Mask Time
8
40
Xtalk Cancel
Mount Type
CymMount
* You need to set each Advanced Trigger Parameter (e.g. Scan Time)
after setting the trigger type.
TD-10
(Non-expanded)
CY-12H
PD7
Trigger Type
Sensitivity
5
Threshold
3
Curve
Linear
Scan Time
1.0
Retrigger Cancel
3
Mask Time
8
40
Crosstalk Cancel
* You need to set each Advanced Trigger Parameter (e.g. Scan Time)
after setting the trigger type.
10
CY-14C
CY-15R
CrB
RdA
8
8
4
4
Linear
Linear
CY-14C
CY-15R
P7B
P7B
8
8
4
4
Linear
Linear
1.0
1.0
10
10
8
8
50
50
CymMount
CymMount
CY-14C
CY-15R
PD7
PD7
5
5
3
3
Linear
Linear
1.0
1.0
3
3
8
8
40
40
TD-8
Pad Type (Trigger Type)
Sensitivity
Threshold
Curve
Scan Time
Retrigger Cancel
Mask Time
Crosstalk Cancel
* You need to set each Advanced Trigger Parameter (e.g. Scan Time)
after setting the trigger type.
TD-7
Cross Talk Group
Velocity Curve
Choke
Max Dyna
Min Dyna
Min Velo
Mask Time
Threshold
* Each trigger parameter can be set independently for the "head-side"
and "rim-side." Set to the same value for the head and rim. Also
trigger parameters can be set in each patch.
TD-5
Trigger Type
Sensitivity
Threshold
Curve
Scan Time
Retrigger Cancel
Mask Time
Crosstalk Cancel
* You need to set each Advanced Trigger Parameter (e.g. Scan Time)
after setting the trigger type.
CY-12H
CY-14C
CY-15R
PD7
PD7
PD7
10
10
10
3
3
3
Linear
Linear
Linear
1.0
1.0
1.0
3
3
3
8
8
8
40
40
40
CY-12H
CY-14C
CY-15R
1
1
1
Norm3
Norm3
Norm3
ON
ON
ON
5
5
5
1
1
1
1
1
1
0
0
0
1
1
1
CY-12H
CY-14C
CY-15R
P 1
P 1
P 1
7
8
8
2
2
2
Lnr
Lnr
Lnr
1.5
1.5
1.5
4
4
4
12
12
12
50
50
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-cymbal cy-14cV-cymbal cy-12h

Table of Contents