Trion HE Plus 1400 Installation Operation & Maintenance

Trion HE Plus 1400 Installation Operation & Maintenance

Trion duct mount electronic air cleaner
Hide thumbs Also See for HE Plus 1400:

Advertisement

'
Warranty
'
ELECTRONIC AIR CLEANER LIMITED THREE-YEAR WARRANTY
This limited warranty covers Trion Residential Type Electronic Air Cleaners, excluding ductwork, wiring, and
installation. Trion warrants that all new Trion Residential Type Electronic Air Cleaners are free from defects in
material and workmanship under normal, noncommercial use and service. Trion will remedy any such defects
if they appear within 36 months from the date of original installation as evidenced by Proof of Purchase from an
Authorized Trion Dealer, subject to terms and conditions of the Limited Three-Year Warranty stated below:
1. THIS LIMITED THREE-YEAR WARRANTY IS GRANTED BY TRION, 101 MCNEILL ROAD, SANFORD,
NC 27330.
2. This warranty shall extend only to any noncommercial owner who has purchased the residential Electronic
Air Cleaner other than for purposes of resale.
3. All components are covered by this limited warranty except expendable items such as charcoal filters.
4. If within the warranty period, any Trion residential Electronic Air Cleaner unit or component requires
service, it must be performed by a competent heating and or air conditioning contractor (preferably the
installing contractor). Trion will not pay shipping charges or labor charges to remove or replace such
defective parts or components. If the part or component is found by inspection to contain such defective
material and workmanship, it will be either repaired or exchanged free of charge at Trion's option, and
returned freight collect.
5. In order to obtain the benefits of this limited three-year warranty, the owner must notify the dealer or
distributor in writing or by phone, of any defect within 30 days of its discovery. If after reasonable time you
have not received an adequate response from the dealer or distributor, notify in writing, by phone, or email:
Trion, 101 McNeill Road, Sanford 27330 / 1-800-884-0002 / customerservice@trioniaq.com.
6. This limited warranty does not apply to any part or component that is damaged in transit or when handling,
has been subject to misuse, neglect or accident, has not been installed, operated and serviced according
to Trion's instruction, has been operated beyond the factory rated capacity, or altered in any such way that
its performance is affected. There is no warranty due to neglect, alteration, or ordinary wear and tear.
Trion's liability is limited to the replacement of defective parts or components and does not include the
payment cost of labor charges to remove or replace such defective parts.
7. TRION WILL NOT BE RESPONSIBLE FOR LOSS OF USE OF ANY PRODUCT, LOSS OF TIME,
INCONVENIENCE, OR ANY OTHER INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES WITH
RESPECT TO PERSON OR PROPERTY, WHETHER AS A RESULT OF BREACH OF WARRANTY,
NEGLECT, OR OTHERWISE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITATION OR EXCLUSION IN THE
PRECEDING SENTENCE MAY NOT APPLY TO YOU.
8. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.
9. Any warranty (express, implied, or statutory), representation, or guarantee other than those set forth
herein, shall expire at the expiration date, of this express limited warranty. SOME STATES DO NOT
ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE LIMITATION IN THE
PRECEDING SENTENCE MAY NOT APPLY TO YOU.
10. Trion reserves the right to make changes in the design and material of its products without incurring any
obligation to incorporate such changes in units completed on the effective date of such a change.
101 McNeill Road, Sanford, NC 27330
(919)775-2201 / Fax (919)774-8771 / 800-884-0002
customerservice@trioniaq.com
www.trioniaq.com
- 26 -
HE Plus 1400
HE Plus 2000
Duct Mount
Electronic Air Cleaner
Installation • Operation • Maintenance
CAUTION: READ INSTALLATION, OPERATION, AND MAINTENANCE
INSTRUCTIONS CAREFULLY FOR SAFE OPERATION. EXERCISE
EXTREME CAUTION WHEN WORKING WITH ELECTRICTY.
155587-001 06-11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HE Plus 1400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trion HE Plus 1400

  • Page 1 PRECEDING SENTENCE MAY NOT APPLY TO YOU. 10. Trion reserves the right to make changes in the design and material of its products without incurring any obligation to incorporate such changes in units completed on the effective date of such a change.
  • Page 2: Table Of Contents

    (for use by authorized HVAC contractors only) Technical Specifications..................Installation Considerations................. Application..................Installation Requirements..............Air Conditioning................. Evaporative Humidifiers..............Atomizing Humidifiers................ HE PLUS 1400 HE PLUS 1400 HE PLUS 2000 Sheet Metal Installation..............DESCRIPTION (16” x 25”) (20” x 20”) (20” x 25”) Transitions..................
  • Page 3: Introduction

    ‘ Installation ‘ ‘ Introduction ‘ ‘ ‘ For Qualified HVAC Installer Only This Electronic Air Cleaner is a two-stage electrostatic precipitator. The air cleaner is Secondary Circuit Power Supply (continued) designed to remove airborne particulates, including dust, dirt, smoke, pollen, virus, spores, bacteria, and mold from indoor air.
  • Page 4: Unit Components

    ‘ Unit Components ‘ ‘ Installation ‘ ‘ ‘ For Qualified HVAC Installer Only Cabinet Secondary Circuit - Power Supply Mounts to existing ductwork; houses the Ionizing-Collecting Cells and Prefilters. If the Red CELL ENERGIZED light remains out with the Ionizing-Collecting Cells removed ®...
  • Page 5: Operation

    ‘ Installation ‘ ‘ Operation ‘ ‘ ‘ For Qualified HVAC Installer Only Regular Dusting and “White Dust” Secondary Circuit - Ionizing-Collecting Cells Your new Electronic Air Cleaner will efficiently clean and filter your household air. It will not eliminate the need for regular dusting of your furniture and belongings. Duct-mounted air The cells are electrically energized through a contact terminal located at the top center of cleaners can only clean air that reaches the air cleaner.
  • Page 6: High Altitude Operation

    ‘ Operation ‘ ‘ Installation ‘ ‘ ‘ For Qualified HVAC Installer Only High Altitude Operation Primary Circuit with HVAC System Blower Operating Because the air is less dense at higher altitudes, there is a possibility of nuisance arcing in the Electronic Air Cleaner.
  • Page 7: Maintenance Of Your Electronic Air Cleaner

    ‘ Installation ‘ ‘ Maintenance ‘ ‘ ‘ For Qualified HVAC Installer Only Washing Ionizing-Collecting Cells and Prefilters Troubleshooting ® Regular washing of the Forever Filter Ionizing-Collecting Cells is necessary to ensure proper performance. A thorough washing once every six months will be adequate for most WARNING: installations.
  • Page 8: Replacing Ionizing Wires In Ionizing-Collecting Cells

    ‘ Maintenance ‘ ‘ Installation ‘ ‘ ‘ For Qualified HVAC Installer Only Replacing Ionizing Wires in Ionizing-Collecting Cells System Checkout Instances of the Ionizing Wires breaking are minimal due to the constant tension design and fixed location of the Ionizing Wire supports. When an Ionizing Wire breaks, the WARNING: efficiency of the Electronic Air Cleaner will decrease slightly.
  • Page 9: Common Questions & Answers

    ‘ Installation ‘ ‘ Questions and Answers ‘ ‘ ‘ For Qualified HVAC Installer Only Common Questions and Answers Electrical Installation Q. Why isn’t my Electronic Air Cleaner cleaning my air? CAUTION: A. The air cleaner is most likely working just like it was designed. However, many factors can affect the performance of the unit.
  • Page 10 ‘ Questions and Answers (continued) ‘ ‘ Installation ‘ ‘ ‘ For Qualified HVAC Installer Only Q. I lost power to my home during a storm. Should I worry about the Electronic Air Cleaner? NOTE: The following is a typical installation of the air cleaner on a highboy furnace. A.
  • Page 11: Common Troubleshooting Techniques

    Reposition output jumper on If you have any questions on installation issues or problems, please call High altitude unit Power Supply Trion Technical Support 800 - 884 - 0002 Uncommon occurrence – Radio or Television Poor electrical ground Ensure air cleaner is...
  • Page 12: Unit Dimensions

    DIM B DIM C DIM D MODEL inches inches inches inches HE PLUS 2000 24-1/4 20-15/16 24-7/8 7-1/8 HE PLUS 1400 20-1/4 16-15/16 24-7/8 7-1/8 HE PLUS 20 X 20 24-1/4 20-15/16 21-3/8 7-1/8 DIM E DIM F DIM G...
  • Page 13: Hvac Installation Instructions

    Technical Specifications This air cleaner is factory set for left to right airflow when you are facing the Front Panel Assembly. Model HE Plus 1400 HE Plus 1400 HE Plus 2000 Right to left airflow: 1. Remove the Prefilters and Ionizing-Collecting Cells from the cabinet. A plastic Dimensions 16”...
  • Page 14: Installation Considerations

    ‘ Installation ‘ ‘ Installation ‘ ‘ ‘ ‘ ‘ For Qualified HVAC Installer Only For Qualified HVAC Installer Only Atomizing Humidifiers Application If an atomizing humidifier is mounted upstream of the air cleaner: The air cleaner is used in forced air heating, cooling, and ventilating systems. It should be installed in the system such that all the system air is circulated through the air cleaner.

This manual is also suitable for:

He plus 2000

Table of Contents