7-2.

Linear Matrix and AWB Adjustment

This adjustment does the following adjustment items automati-
cally.
Linear matrix adjustment
Compensate the dispersion of the linear matrix vale of the
CCD imager.
AWB 3200K/5800K (Mon) standard data input
Acquire the white balance standard data at 3200K and 5800K
in monitoring mode.
AWB 3200K/5800K (Cap) standard data input
Acquire the white balance standard data at 3200K and 5800K
in capture mode.
STILL (P AUTO) ( P )
Mode
Subject
9 colors chart (PTB-1450)
(Standard picture frame)
About 6cm from the front of the lens
Adjustment Page
6E
Adjustment Address
80 to 9F (Linear matrix adjustment)
04 to 21, 24 to 49 (AWB 3200K/
5800K standard data input)
Switch setting:
Mode dial ............................................ STILL (P AUTO) ( P )
ZOOM .................... WIDE end (Turn the zoom ring to "28")
MACRO ............................................................................. ON
FOCUS ................................................................... MANUAL
Adjusting method:
1) Install the camera for adjustment.
2) Start the DSC-F828 C1 MATRIX ADJ on the PC.
[Connect]
3) Click
on the DSC-F828 C1 MATRIX Adjustment
screen.
4) Set up the switches of the camera as above-mentioned.
5) Shoot the 9 colors chart with the standard picture frame. (Re-
fer to "4. Picture Frame Setting (PTB-1450)".
6) Adjust the focus..
[Linear Matrix and AWB Adjustment]
7) Click
C1 MATRIX Adjustment screen.
Fig. 6-1-38
DSC-F828
8) The following adjustments are performed automatically.
Linear matrix adjustment
AWB 3200K/5800K (Mon) standard data input
AWB 3200K/5800K (Cap) standard data input
Note: When the "Framing check" message is displayed, correct
When the "File C:\ProgramFiles\Sony\F828C1MATRIX\
GodRawData.CSV can not be open" message is displayed, the
reference data file (GodRawData.CSV) for the liner matrix ad-
justment is not in the inside of the PC. Therefore, perform "7-1.

Preparation (Get Reference Data)".

on the DSC-F828
9) When the "Completion of adjustment" message is displayed.
Click the
6-20
the picture frame, and repeat from step 7).
Fig. 6-1-39
Fig. 6-1-40
[OK]
button.
Fig. 6-1-41