Vector ZCB Single Board Computer
Synchronous
Rates
Synch detect
Clock
Parity
Data bits
Sync character
Parallel Ports
Port Addresses
latching
Signal level
Number of lines
Data transfer
Cable
Rev. 1-B
6/11/80
OC-56K.
Can
be
wired for internal or external synch.
8251 SYNDET line is not connected.
r-bt now connected to the external \\GrId as required
for synchronous operation.
Even
I
odd, or none, prograrmnable
5 - 8, prograrmnable
Single or double synch character can
be
progrannned.
2-8 bit, 2-4 bit can
be
programmed as 3-8 bit.
Uses
an 8255 parallel I/O controller chip.
Any increment of four from OOH to PFH.
Preset
addresses are: Port A, 08H: Port B, 09Hi Port C, OAH
and the Control Status Register at DBH.
Output latched, input not latched.
'ITL (input
=
1 low power TIL load: output drives 1 TI'L
load) •
8 lines per channel, programmable for input or output.
+5 VDC and GND are also provided.
Over lOOK bytes/second.
Optional. Has 34-pin female connector and 34-line
ribbon cable.
No
connector is at the
ot..~er
end,
allowing user to configure as required.
Must
be
ordered separately.