Connecting Power and Data

Connecting Power
The luminaire requires standard AC power distribution from 208-240 VAC, 50/60 Hz. Current required depends on the AC supply voltage
and product model. Refer to
Note: The mating Neutrik® powerCON® True1 connector is supplied; however, you will need to purchase or construct a cable appropriate
for your application. Available power input cables is found in
Depending on the application, the luminaire's AC input cable may require a different connector. If required, install a new connector meeting
your requirements using the following wire color code reference:
WARNING: DO NOT connect to three-phase service in countries with 240 volt power. AVERTISSEMENT: NE PAS se connecter au
service en trois phases dans les pays avec puissance de 240 volts.
For single-phase power at 240 volts RMS:
For three-phase power at 208 volts RMS:
WARNING: It is not recommended to power any VARI❋LITE luminaire from a dimmer - even in 'NONDIM' mode. Dimmer and non-dim
modules are not suitable sources of power because their output modifies the AC wave form. This may work for a short time, but will
eventually result in power problems, luminaire mis-operation and/or failure and may void the luminaire's warranty. AVERTISSEMENT: Il
n'est pas recommandé pour alimenter un luminaire VARI❋LITE d'un gradateur - même en mode 'NONDIM. Modules de gradation et non
sombres ne sont pas des sources appropriées de pouvoir parce que leur production modifie la forme d'onde AC. Cela peut fonctionner
pendant une courte période, mais finira par entraîner des problèmes d'alimentation, luminaires mauvais fonctionnement et / ou l'échec et peut
annuler la garantie de l'appareil.
02 .9 704 .00 01 0
VARI❋LITE - VL4000 S
"Current vs. Voltage" on page 7
Figure 2: Power Connector
Wire*
Green/Yellow
Blue
Brown
* International (Harmonized) Standard
Connection
AC Neutral
AC Line
Ground (Earth)
Connection
Phase 1
Phase 2
Ground (Earth)
05 Ju ne 2014
POT
for all models covered in this manual.
"Replacement Items/Accessories" on page
AC Power Input
3-Pole Neutrik® powerCON® True1 for AC Input Power
Neutrik® powerCON® True1
Connection
AC Ground
AC Neutral
AC Line
Pin
X
X
Y
Y
G
Pin
X
X
Y
Y
G
L