Outlines And Dimensions - Mitsubishi Electric Mr.Slim MUZ-GC25NA - C1 Service Manual

Outdoor unit split-type air conditioners
Table of Contents

Advertisement

3

OUTLINES AND DIMENSIONS

MUZ-GC25NA MUZ-GC35NA
381.5
Air in
Air out
17.5
Handle
243
105
Bolt pitch for installation
MUZ-GC50NA MUZ-GC60NA MUZ-GC71NA
299
66
169
Air in
40
2 holes 10×16
61
500
684
515
40
500
80
840
121
REQUIRED SPACE
Open two sides of left,
right, or rear side.
255
Service panel
20.8
Liquid refrigerant pipe joint
Refrigerant pipe (flared) ø6.35
Gas refrigerant pipe joint
Refrigerant pipe (flared) ø9.52
Service port
145.5
REQUIRED SPACE
100 mm or more
Open as a rule
500 mm or more if the back,
both sides and top are open
198
8
Basically open 100 mm or more
without any obstruction in front
and on both sides of the unit.
Open as a rule
500 mm or more if
the front and both
sides are open
100 mm or more
200 mm or more if
there are obstacles
to both sides
350 mm or more
Service panel
Liquid refrigerant
pipe joint
Refrigerant pipe
(flared) ø6.35 (MUZ-GC50/60)
ø9.52 (MUZ-GC71)
Gas refrigerant
pipe joint
Refrigerant pipe
(flared) ø12.7 (MUZ-GC50)
ø15.88 (MUZ-GC60/71)
Unit : mm