Outdoor model
Function
Power supply
Capacity Rated frequency
(Min.-Max.)
Power outlet
Running current 1 (Total)
Power input 1 (Total)
Power factor 1 (Total)
Starting current 1 (Total)
Coeffi cient of performance (C.O.P) 1
(Total)
Model
Compressor
Output
Current 1
Model
Fan motor
Current 1
Dimensions W×H×D
Weight
Dehumidifi cation
Air fl ow 1
Sound level 1 (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant fi lling capacity
(R410A)
Refrigeration oil (Model)
NOTE : Test conditions are based on CNS 14464, ISO 5151.
Cooling : Indoor
Outdoor Dry-bulb temperature 35°C
Heating : Indoor
Outdoor Dry-bulb temperature 7°C
1 Measured under rated operating frequency.
MUZ-GC50NA
Cooling
kW
5.0 (1.2-5.8) 5.6 (1.2-7.8) 6.0 (1.2-6.7) 6.8 (1.2-8.1) 7.1 (1.4-8.3) 8.1 (1.4-9.6)
A
8.26
C1
A
8.08
C2
1,800
C1
W
1,760
C2
%
99
C1
A
C2
2.78
C1
2.84
C2
SNB130FLDH1
C1
SNB130FGBH
C2
W
A
7.59
A
mm
kg
/h
1.7
m
/h
2,940/1,650 2,940/2,210 2,940/1,650 2,940/2,210 2,940/1,650 2,940/2,210
3
dB (A)
52/51
rpm
800/480
kg
Dry-bulb temperature 27°C
Dry-bulb temperature 20°C
MUZ-GC60NA
Heating
Cooling
Single phase 220 - 230 V, 60 Hz
10.33
C1
8.22
10.05
C2
2,160
C1
1,790
2,100
C2
99
95
8.26
C1
8.22
C2
2.78
C1
3.13
2.86
C2
SNB130FLDH1
C1
SNB130FGBH
C2
850
7.55
9.41
RC0J60-AA
840 × 850 × 330
53
1.6
55/53
53/51
800/620
800/480
1.5
Wet-bulb temperature
Wet-bulb temperature
5
MUZ-GC71NA
Heating
Cooling
20
9.72
12.03
2,010
2,540
94
96
10.33
10.05
3.38
2.80
TNB220FMCHT
8.80
11.11
0.32
2.5
55/53
53/51
800/620
800/480
2
1.8
NEO22
19°C
6°C
Heating
11.96
2,500
95
12.03
3.24
1,300
11.04
58
55/53
800/620
2

Hide quick links: