Kenwood TK-3302 Service Manual page 30

Uhf fm transceiver
Hide thumbs Also See for TK-3302:
Table of Contents

Advertisement

TK-3302/3302
Item
Condition
6. QT Fine
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Wide]
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
[Narrow]
2) TEST CH: Center
PTT: ON
7. DQT Fine
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Wide]
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
[Narrow]
2) TEST CH: Center
PTT: ON
8. DTMF Fine
1) TEST CH: Center
Deviation
Deviation meter fi lter
[Wide]
LPF: 15kHz
HPF: OFF
PTT: ON
[Narrow]
2) TEST CH: Center
PTT: ON
9. MSK Fine
1) TEST CH: Center
Deviation
Deviation meter fi lter
[Wide]
LPF: 15kHz
HPF: OFF
PTT: ON
[Narrow]
2) TEST CH: Center
PTT: ON
Receiver Section
Item
Condition
1. BPF Wave
1) Center frequency
Adjust
Spectrum analyzer setting
AK,AP,UK,
Center-f: 470MHz
AM,BM
Span: 200MHz
RBW: 100kHz
VBW: 10kHz
ATT: 10dB
2) High-edge frequency
Spectrum analyzer setting
Center-f: 490MHz
3) Low-edge frequency
Spectrum analyzer setting
Center-f: 450MHz
30
U
/3306
(
)
ADJUSTMENT
Measurement
Test-
Unit
equipment
Power
meter
Deviation
meter
Oscilloscope
AG
AF VTVM
Measurement
Test-
Unit
equipment
SSG
Spectrum
TX-RX
analyzer
Adjustment
Terminal
Unit
Parts
ANT
FPU
0.75kHz
SP/MIC
connector
0.38kHz
0.75kHz
0.38kHz
3.0kHz
1.5kHz
3.0kHz
1.5kHz
AK: TK-3302 K AP: TK-3302 P UK: TK-3302(U) K
AM: TK-3302 M BM: TK-3306 M BM3: TK-3306 M3
Adjustment
Terminal
Unit
Parts
ANT
FPU
Adjust the waveform
as shown to the Fig.
BPF
1~3.
Specifi cations / Remarks
Method
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
±100Hz
±100Hz
Specifi cations / Remarks
Method

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-3302uTk-3306Tk-3300

Table of Contents