Common Section
Item
Condition
1. Setting
1) BATT terminal votage: 7.5V
2) SSG standard modulation
[Wide]
MOD: 1kHz, DEV: 3kHz
[Narrow]
MOD: 1kHz, DEV: 1.5kHz
2. VCO lock
1) CH: High
voltage
RX
2) CH: Low
3. VCO lock
3) CH: High
voltage
PTT: ON
TX
4) CH: Low
PTT: ON
Transmitter Section
Item
Condition
1. Frequency
1) CH: High
Adjust
PTT: ON
2. High
1) TEST CH: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
PTT: ON
3. Low
1) TEST CH: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
PTT: ON
4. Maximum
1) TEST CH: Center, Low, High
Deviation
(3 points)
[Wide]
AG: 1kHz/150mV
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
PTT: ON
[Narrow]
2) TEST CH: Center
PTT: ON
5. DQT
1) TEST CH: Center, Low, High
Balance
(3 points)
[Wide]
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
PTT: ON
[Narrow]
2) TEST CH: Center
PTT: ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
ANT
TX-RX
meter
DVM
TX-RX
LV (CV)
TX-RX
Measurement
Test-
Unit
Terminal
Unit
equipment
f. counter
ANT
TX-RX
Power
meter
Ammeter
Power
ANT
meter
Deviation
meter
Oscilloscope
AG
SP/MIC
AF VTVM
connector
TK-3302/3302
Adjustment
Parts
Method
TC1
3.4V
±0.1V
AK,AP,UK,AM, BM
3.0V BM3
Check
0.6V or more
TC2
3.1V
±0.1V
AK,AP,UK,AM, BM
3.0V BM3
Check
0.6V or more
AK: TK-3302 K AP: TK-3302 P UK: TK-3302(U) K
AM: TK-3302 M BM: TK-3306 M BM3: TK-3306 M3
Adjustment
Parts
Method
VR1
High frequency
±50Hz
FPU
4.0W±0.1W
2.0A or less
1.0W±0.1W
1.0A or less
4.4kHz (According to
±80Hz
the lager +, –)
2.2kHz (According to
±80Hz
the lager +, –)
Make the demodu-
lation wave into
square waves.
U
/3306
(
)
Specifi cations / Remarks
Specifi cations / Remarks