Lennox EL195UHE Elite Series Installation Instructions Manual page 24

Elite series gas furnace upflow / horizontal air discharge
Hide thumbs Also See for EL195UHE Elite Series:
Table of Contents

Advertisement

Maximum Allowable Exhaust Vent Pipe Length Without Insulation In Unconditioned Space For
Winter Design Temperatures Single − Stage High Efficiency Furnace
Winter Design
1
Temperatures
°F (°C)
32 to 21
(
0 to −6)
20 to 1
(−7 to −17)
0 to −20
(−18 to −29)
1
Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Fundamentals Handbook.
NOTE − Maximum unisulated vent lengths listed cannot exceed the maximum allowable intake or exhaust vent length listed in table 5.
TABLE 7
Vent Pipe
Diameter
045
2 in.
26
2−1/2 in.
18
3 in.
14
2 in
16
2−1/2 in.
12
3 in.
9
2 in.
10
2−1/2 in.
8
3 in.
4
Page 24
Unit Input Size
070
090
44
44
32
50
26
38
28
40
20
30
16
26
20
30
14
20
10
16
110
135
24
N/A
58
N/A
55
60
24
N/A
44
N/A
32
40
24
N/A
32
N/A
26
30