Other products from GSD “Wireless Network System” GSD Wi-Max System is the next generation in access control solutions. It provides a Contents Wireless Network throughout the premises, giving the convenience and security of a fully networked system for a fraction of the cost.
Page 2
Technical Specification Installation Steps Installation Steps Technical Specs - GSD Wi-Plus Controller Power Supply 12 DC Current consumption 120mA Step Description Page Current consumption with load (max) 160mA Install the Controller using the Installation Diagrams Relay Contact Rating 5 Amps /240V ac...
Installation Diagrams Installation Diagrams 1. To open front cover of GSD Controller, remove screw cap using screwdriver then loosen screw. 3. screw the rear enclosure to the wall. as shown below. 2. Remove door from unit (see inset) before screwing the rear enclosure to the wall.
System Overview System Overview RS485 Connection to Door Controls Wireless Connection to Door Controls RS485 Network to Controllers Note: If using a single Controller, Note: If using a single Controller, RS485 Network to Controllers Max number of Controllers 3 an RS232 cable may be used. an RS232 cable may be used.
Note : Used ONLY for Wired 485 Network 12V Linear Connections. Power supply PC Direct Connection can be used, when using ONLY one GSD Controller. Set the Direct address to ALL dip switches OFF (see below ) Inputs 3V Lithium...
Page 6
All dip-swithces ON. The dip-switchess should then be set to the controller Address 1 - Set SW1 ON Address 2 - Set SW2 ON Address 3 - Set SW3 ON address as shown above in section “Setting the GSD controller address”...
Creating a new network will overwrite any existing network information and any enrolled Door Controls will be un-enrolled. All Door Controls will Follow instructions on the CD provided to install the GSD PC application. have to be defaulted and re-enrolled on the new network that has just...
Page 8
Operation Instructions Operation Instructions Phase 3 - Enrolling Door Controls Phase 3 - Enrolling Door Controls Step Description Step Description The controller is now ready to allow Door Controls to enrol onto the All Door Controls should be installed at this point and powered up. Network –...
Page 9
Operation Instructions Operation Instructions Phase 4 - Configuring Users Phase 3 - Enrolling Door Controls Step Description Step Description Once all Door Controls are enrolled onto the network – go back to the Enable a User by ticking the ‘Enabled’ box for each User Controller application and click the ‘Secure Network’...
Operation Instructions Operation Instructions Enrolling User FingerPrints Phase 5 - Configuring Access Levels Step Description Step Description Access Levels are controlled by creating UserGroups and assigning the Note: Make sure the USB Fingerprint reader is attached to the PC UserGroup to a User as decribed in section ‘Configuring Users’. Select the User for fingerprint enrollment UserGroups are created by combining pairs of DoorGroups with Timezones.
Page 11
Finger Placement Wi-BIO Finger Placement Wi-BIO Correct Finger Placement Incorrect Finger Placement Note: Incorrect placement : finger does not fully cover the sensor window. Good Quality Image Poor Quality Image Note: Ensure that the core of finger is centered on the sensor window during the enrollment process.
Need help?
Do you have a question about the Wi-Plus Controller and is the answer not in the manual?
Questions and answers