6 Technical Data

Dimensions and weight
Dimensions L x W x H (mm) with DB9
Weight
Ambient conditions
Operating temperature
Storage temperature
Humidity:
Isolation class
Power supply and operating hours
Battery
Standby
Cable testing
Tone generator
Auto power OFF
Ethernet Test
Cable types
Pair resistance to pass test
Shield resistance to pass test
Cable length for split pair test
Coax Test
Resistance
PN1-Manual-EN.docx
13,2 × 7,3 × 4,1 cm (5,2 × 2,9 × 1,6 inches)
242 g (8,5 oz.) with battery and Remote Unit
0 to 50 °C (32 to 122 °F)
-10 to 60 °C (14 to 140 °F)
10 % to 90 %, non-condensing
IP 20 (DIN 40 050)
9 V Alkaline battery
2,5 years
150 hours
250 hours
After 9 minutes the last button was pressed in cable
testing modes and after 2,4 hours in tone mode
Data network cable, CAT6, CAT-5E, CAT-5, CAT-4, CAT-
3
Maximum 200 Ohm
Maximum 100 Ohm
Minimum 2 m cable for testing of split pairs
Maximum 100 Ohm DC resistance, conductor plus shield
_______________________________________________
Version 1.2.1 – June 2014
PROFINET Cable Tester – User Manual
© PROCENTEC 2014 - Copyright - all rights reserved
Page 18 / 32