Mitsubishi Electric MSC-GE-VB Service Manual page 33

Split-type
Hide thumbs Also See for MSC-GE-VB:
Table of Contents

Advertisement

MXZ-2B40VA MXZ-2B52VA
Discharge temperature (°C)
More than Target discharge temperature + 10
Target discharge temperature + 10 to Target discharge temperature + 5
Target discharge temperature + 5 to Target discharge temperature + 2
Target discharge temperature + 2 to Target discharge temperature - 2
Target discharge temperature - 2 to Target discharge temperature - 5
Target discharge temperature - 5 to Target discharge temperature - 10
Target discharge temperature - 10 or less
MXZ-3B54VA MXZ-3B68VA MXZ-4B71VA
MXZ-3C54VA MXZ-3C68VA MXZ-4C71VA
Discharge temperature (°C)
More than Target discharge temperature + 10
Target discharge temperature + 10 to Target discharge temperature + 5
Target discharge temperature + 5 to Target discharge temperature + 2
Target discharge temperature + 2 to Target discharge temperature - 2
Target discharge temperature - 2 to Target discharge temperature - 5
Target discharge temperature - 5 to Target discharge temperature - 10
Target discharge temperature - 10 or less
MXZ-4B80VA MXZ-5B100VA
MXZ-4C80VA MXZ-5C100VA
Discharge temperature (°C)
More than Target discharge temperature + 12
Target discharge temperature + 12 to Target discharge temperature + 5
Target discharge temperature + 5 to Target discharge temperature + 3
Target discharge temperature + 3 to Target discharge temperature - 3
Target discharge temperature - 3 to Target discharge temperature - 5
Target discharge temperature - 5 to Target discharge temperature - 12
Target discharge temperature - 12 or less
MXZ-6C120VA
Discharge temperature (°C)
More than Target discharge temperature + 12
Target discharge temperature + 12 to Target discharge temperature + 5
Target discharge temperature + 5 to Target discharge temperature + 3
Target discharge temperature + 3 to Target discharge temperature - 3
Target discharge temperature - 3 to Target discharge temperature - 5
Target discharge temperature - 5 to Target discharge temperature - 12
Target discharge temperature - 12 or less
LEV opening correction (pulse)
COOL
5
4
2
0
-1
-3
-4
LEV opening correction (pulse)
COOL
5
4
2
0
-1
-3
-4
LEV opening correction (pulse)
COOL
4
2
1
0
-1
-3
-8
LEV opening correction (pulse)
COOL
4
2
1
0
-1
-3
-8
33
HEAT
8
3
1
0
-1
-2
-3
HEAT
8
3
1
0
-1
-2
-3
HEAT
6
2
1
0
-1
-2
-8
HEAT
6
2
1
0
-1
-2
-8