VII. MAINTENANCE
PREVENTATIVE MAINTENANCE
See ORB 4-20mA Input Box IOM for specific maintenance and possible replacement parts for the ORB 4-20mA
Input Box unit. There is no preventative maintenance for a single unit radio.
REPLACEMENT PARTS
LUC044016
Extended Range Antenna, 2 ft (61 cm) Connection Cable
LUC044023
Extended Range Antenna, 10 ft (3 m) Connection Cable
LUC044005
Extended Range Antenna Lightening Arrestor
VIII. TROUBLESHOOTING
For technical or service questions, please call the manufacturer Customer Support at 1-800-778-9242.
For detailed dimensional drawings, go to www.bindicator.com.
SYMPTOM
RSSI LEDs not on
Red Indicator LED is not
on
Top and or middle
Indicator LEDs is not
flashing
POSSIBLE CAUSE
Radio(s) are not powered on
Protocol switches do not match
Antenna not connected
Not wired correctly
Both (all) radios may not be powered
on
Units are not communicating
CORRECTIVE ACTION
Make sure the Indicator LED is red; if not
check wiring
Check dip switches and change if needed
Tighten antenna and put in most direct line
of sight to other radio
Reference wiring diagrams and check
wiring
Make sure the Indicator LED is red; if not
check wiring on both (all) units.
Check all wiring
10