Dimplex KSS 2508 AIV Installation And Operating Instructions Manual
Dimplex KSS 2508 AIV Installation And Operating Instructions Manual

Dimplex KSS 2508 AIV Installation And Operating Instructions Manual

Split air conditioner for wall mounting

Advertisement

Installation and Operating Instructions
Split Air Conditioner for Wall Mounting
KSS 2508 AIV
KSS 3508 AIV
KSS 4508 AIV
Technical data ............................................................................................................................. 2
Energy efficiency ......................................................................................................................... 3
Checklist ...................................................................................................................................... 4
Refrigeration plan ........................................................................................................................ 4
Safety regulations ........................................................................................................................ 5
Device construction ..................................................................................................................... 6
Installation instructions ................................................................................................................ 7
Scope of supply ........................................................................................................................... 7
Minimum clearances.................................................................................................................... 8
Assembling the indoor unit .......................................................................................................... 9
Assembling the outdoor unit ...................................................................................................... 10
Refrigerant pipes ....................................................................................................................... 11
Connecting the refrigerant pipes on the outdoor unit ................................................................. 12
Electrical Connection ................................................................................................................. 13
Start-up...................................................................................................................................... 13
Important notes on operation..................................................................................................... 14
Circuit diagram........................................................................................................................... 15
Operation................................................................................................................................... 18
Cleaning and maintenance ........................................................................................................ 21
Faults......................................................................................................................................... 22
Warranty, after-sales service ..................................................................................................... 23
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KSS 2508 AIV and is the answer not in the manual?

Questions and answers

Summary of Contents for Dimplex KSS 2508 AIV

  • Page 1: Table Of Contents

    Installation and Operating Instructions Split Air Conditioner for Wall Mounting KSS 2508 AIV KSS 3508 AIV KSS 4508 AIV Technical data ..........................2 Energy efficiency ......................... 3 Checklist ............................4 Refrigeration plan ........................4 Safety regulations ........................5 Device construction ........................6 Installation instructions ........................
  • Page 2: Technical Data

    Technical data Split room conditioners KSS 2508 AIV KSS 3508 AIV KSS 4508 AIV Indoor unit KSS 2508 AIV I KSS 3508 AIV I KSS 4508 AIV I Outdoor unit KSS 2508 AIV A KSS 3508 AIV A KSS 4508 AIV A Cooling capacity / heat output 2.50 / 2.70...
  • Page 3: Energy Efficiency

    Energy efficiency Energy Room air conditioner Manufacturer: Dimplex Dimplex Dimplex Outdoor unit KSS 2508 AIV A KSS 3508 AIV A KSS 4508 AIV A Indoor unit KSS 2508 AIV I KSS 3508 AIV I KSS 4508 AIV I Low energy consumption...
  • Page 4: Checklist

    Checklist • Has a calculation of the cooling load been made? • Is the cooling capacity of the device sufficient for the room to be cooled? • Are the operating limits sufficient for the purpose for which the air conditioner is intended? •...
  • Page 5: Safety Regulations

    Safety regulations General • Please read these installation and operating instructions carefully and fully before commencing installation! They contain important information about the assembly, use and maintenance as well as safety instructions to be observed! • After unpacking the device, inspect it for any transport damage. In case of doubt, do not put the device into use but have it examined by a qualified technician.
  • Page 6: Device Construction

    Device construction Indoor unit Air inlet Airflow fins (for adjustable air outlet direction) Air outlet Signal receiver (of the remote control) with indicator lamps Mains connection cable on indoor unit Outdoor unit Air inlet Air outlet 10 Connection lines indoor unit - outdoor unit 11 Condensate outflow hose...
  • Page 7: Installation Instructions

    Forms for cooling load calculation complete with instructions can be obtained from the manufacturer or wholesaler or on the Internet at www.dimplex.de Indoor or outdoor units, which are not installed according to instructions, may cause a reduction or loss of warranty in case of...
  • Page 8: Minimum Clearances

    Minimum clearances All dimensions in mm...
  • Page 9: Assembling The Indoor Unit

    Assembling the indoor unit Installation instructions Bends in the refrigerant pipes may not be positioned immediately before or after refrigerant couplings! Wall Indoor unit If it does not matter whether the pipes are visible in the room, they can be led out of the side of the indoor unit to the left and routed through the wall at some other suitable location.
  • Page 10: Assembling The Outdoor Unit

    Dim. A Dim. B Dim. C Dim. D Dim. E KSS 2508 AIV KSS 3508 AIV KSS 4508 AIV Condensate drainage in the outdoor unit During heating operation there is a formation of condensate which must be drained. There is a hole (diam. 25) for condensate drainage in the base plate of the outdoor unit into which the condensate drainage plug supplied can be inserted.
  • Page 11: Refrigerant Pipes

    Refrigerant pipes Technical information The refrigerant pipes, the indoor and outdoor units are pre-filled with refrigerant R410A. The refrigerant R410A belongs to group 1 of refrigerants according to VBG 20. It is non-combustible and does not cause serious damage to human health. The following must be observed when installing refrigerant pipes: •...
  • Page 12: Connecting The Refrigerant Pipes On The Outdoor Unit

    Connecting the refrigerant pipes on the outdoor unit Important information • Preventing dirt and moisture from entering the system is imperative; clean all connections with a dry cloth, if necessary. • The coupling connections may be loosened or opened again after connecting them, if required. Avoid frequent opening. •...
  • Page 13: Electrical Connection

    Electrical Connection Electrical connection on the outdoor unit Remove the cover, open the strain relief clamp, plug in the plug, fasten the grounding wire to the mounting plate, fasten the electrical cable to the strain relief clamp, attach the cover again. Electrical connection on the indoor unit The power supply of the indoor unit and the outdoor unit is done via the pre-installed connecting cable with power plug on...
  • Page 14: Important Notes On Operation

    Information on the efficient use of the device Important notes on operation • Keep windows and doors closed during air conditioning! Use the air conditioner only for the following purposes: • Select the suitable setting of the airflow direction • for room cooling, direct the airflow downward in heating operation, •...
  • Page 15: Circuit Diagram

    Circuit diagram KSS 2508 Indoor unit Outdoor unit...
  • Page 16 Circuit diagram KSS 3508 Indoor unit Outdoor unit...
  • Page 17 Circuit diagram KSS 4508 Indoor unit Outdoor unit...
  • Page 18: Operation

    Operation Operating display on the remote control Function buttons of remote control Fan speed is determined automatically Remote control Fan on Display window Fan speed low / normal / high Select operating mode Send - default is sent. Automatic / Cooling / Dehumidifying / Circulation / Dehumidifying operating mode Heating Heating operating mode...
  • Page 19 Inserting the batteries in the remote control Setting the fan speed Remove the cover of the battery compartment. The fan speed can be set at three levels. The fan speed is set with the FAN (12) button. Insert two 1.5 V MICRO AAA batteries in the battery ”...
  • Page 20 Automatic mode Swing operation Up – down air flow Depending on the room temperature, the operating modes COOLING and HEATING are determined automatically. The Swing operation can be turned on and off using the The temperature cannot be set manually. SWING (4) button.
  • Page 21: Cleaning And Maintenance

    Cleaning and maintenance The device must be disconnected from the mains and Auxiliary filter allowed to cool down before cleaning and maintenance. Remove the two auxiliary filters, if present, as well. Clean the surfaces of the casings with a soft damp cloth and then dry them.
  • Page 22: Faults

    Faults In case of malfunction, stop the operation of the air conditioner immediately, deactivate the unit and disconnect from the mains. Switch off the automatic circuit breaker in the manifold and pull of the mains plug, if necessary. Contact the after-sales service. You can detect possibly impaired function by a reduced output, smoke development, unusual odours, loud noises, increased tripping of the fuse or unusual heat development.
  • Page 23: Warranty, After-Sales Service

    In case of a situation requiring service, the authorised after-sales service for complete systems on site is notified who will quickly remedy the problem. You can find out about the after-sales service for complete systems responsible for your area by contacting the central service hotline of Glen Dimplex Deutschland GmbH. Glen Dimplex Deutschland GmbH...
  • Page 24 Note on disposal Do not dispose of the unit with general household waste. The device must be taken to a local waste disposal plant. Glen Dimplex Deutschland GmbH Telephone: +49 (0) 9221 709 562 Subject to technical changes Am Goldenen Feld 18 Fax: +49 (0) 9221 709 565 Internet: www.dimplex.de...