4.2 Positioning

200
710
(100)
Dimensions without brackets: excl. thermal insulation
Dimensions inside brackets: incl. thermal insulation
*1
Required space for cleaning, heating−up and re−fuelling.
Overall length
79
SA
Safety connection
(safety valve)
TAS Coupling R ½" for the sensor of the
thermostatic drain valve
WW Hot water outlet of the
safety heat exchanger
(no DHW connection)
(480)
(480)
580
580
935
200
710
(100)
4 Vitolig 200
80
679
508
369
183
AGA
KV/SA
KV WW
KW
KR
KR
579
E
460
Dimensions
Rated output
kW
13 to 26
range
a
mm
1 325
b
mm
1 251
c
mm
1 029
d
mm
909
e
mm
1 255
H No air contamination through
halogenated hydrocarbons (e.g. as
contained in sprays, paints, solvents
and cleaning agents).
H Avoid very dusty conditions.
H Avoid high levels of humidity.
H Avoid danger of freezing and ensure
good ventilation.
Otherwise the system may suffer faults
and damage.
The boiler may only be installed in
rooms, where air contamination through
halogenated hydrocarbons may occur,
such as through hairdressing salons,
printing shops, chemical cleaners,
laboratories etc., if adequate measures
can be taken to provide uncontaminated
combustion air.
If in doubt, please contact us.
If these instructions are not observed, any
consequential losses directly related to
any of these causes, are excluded from
our warranty.
TAS
20 to 40
1 525
1 451
1 229
1 109
1 455
31