Konica Minolta magicolor 2400W User Manual page 82

Konica minolta printer user's guide 2400w
Hide thumbs Also See for magicolor 2400W:
Table of Contents

Advertisement

Symptom
Image is
blurred;
background
is lightly
stained;
there is
insufficient
gloss of the
printed
image.
The print or
color density
is uneven.
Irregular
print or mot-
tled image
appears.
76
Cause
One or more of the
toner cartridges are
defective.
The drum cartridge is
defective.
One or more of the
toner cartridges are
defective or low.
The drum cartridge is
defective.
The printer is not
level.
The media is moist
from humidity.
Unsupported media
(wrong size, thick-
ness, type, etc.) is
being used.
One or more of the
toner cartridges are
defective.
The drum cartridge is
defective.
The fuser separator
levers are adjusted
for envelope printing.
Solving Problems with Printing Quality
Solution
Remove the toner cartridge and check
for damage. If it is damaged, replace it.
Remove the drum cartridge and check
for damage. If it is damaged, replace it.
Install new toner cartridges.
Remove the drum cartridge and check
for damage. If it is damaged, replace it.
Put the printer on a flat, hard, level sur-
face not to exceed ±1° slant in any
direction.
Adjust the humidity in the media stor-
age area.
Remove the moist media and replace it
with new, dry media.
Use KONICA MINOLTA-approved
media. See "Media Specifications" on
page 20 for supported sizes.
Remove the toner cartridge and check
for damage. If it is damaged, replace it.
Remove the drum cartridge and check
for damage. If it is damaged, replace it.
Return the fuser separator levers to the
plain paper setting.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents