PREINSTALLATION INSTRUCTIONS FOR DEALERS: The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. The dealer should read this page and guide the installer regarding hardness, day override, time of regeneration, service alarm and buzzer alarm settings before installation.
BYPASS VALVE: The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance. The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have pressure to test a system while providing untreated bypass water to the building.
INSTALLATION: GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere.
7. INSTALLING GROUND: To maintain an electrical ground in metal plumbing of a home’s cold water piping (such as a copper plumbing system), install a ground clamp or jumper wiring. NOTE: If replacing an existing softener, also replace the ground clamps/wire. If removing a softener, replace the piping with the same type of piping as the original to assure plumbing integrity and grounding.
PROGRAMMING PROCEDURES: 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. STEP 1 –...
Page 8
REGENS PER DAY 4 PER NOTE: This valve has the capability of regenerating up to six times in one day. and + buttons simultaneously, then This can be observed by pressing the CLOCK using + or — buttons to toggle the correct number of regenerations per day as desired (see example to right).
OPERATING DISPLAYS AND INSTRUCTIONS: 1. GENERAL OPERATION: When the system is operating, one of five displays may be shown and will alternate with the installing dealer’s name and phone number for future service. Pressing will alternate between the displays. NEXT 1.
Page 10
Once a manual regeneration is initiated, the unit will go into the FILL position. MANUAL REGENERATION This position allows water to enter the brine tank until it reaches the proper level. Once this position is complete, you will notice a 240 Minute (4 hours) REGEN TODAY and TIME OF DAY SOFTENING position.
DOWNFLOW REGENERATING UNITS: START-UP INSTRUCTIONS FOR FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1. Rotate bypass handles to the bypass mode (see Fig. 2 of page 4). 2.
UPFLOW REGENERATING UNITS: START-UP INSTRUCTIONS FOR FLUSHING OF SYSTEM: To flush the system of any debris and air after installation is complete, please perform the following steps: 1. Rotate bypass handles to the bypass mode (see Fig. 2 of page 4). 2.
TROUBLESHOOTING GUIDE: PROBLEM CAUSE CORRECTION A. No power at electric outlet A. Repair outlet or use working outlet B. Control valve power adapter not plugged into B. Plug power adapter into outlet or connect outlet or power cord end not connected to PC power cord end to PC board connection board connection 1.
Page 14
TROUBLESHOOTING GUIDE cont’d: PROBLEM CAUSE CORRECTION A. Turn bypass handles to place bypass in A. Bypass valve in bypass position service position 7. Control valve does not B. Meter is not connected to meter connection on B. Connect meter to three pin connection labeled regenerate automatically PC board METER on PC board...
Page 15
PROBLEM CAUSE CORRECTION A. Injector is plugged A. Remove injector and clean or replace B. Faulty regenerant piston B. Replace regenerant piston C. Regenerant line connection leak C. Inspect regenerant line for air leak 12. Control valve fails to D. Drain line restriction or debris cause excess D.
Page 16
TROUBLESHOOTING GUIDE cont’d: PROBLEM CAUSE CORRECTION D. Verify that proper voltage is being supplied. 15. E2, Err – 1002, Err – Press NEXT and REGEN buttons for 3 seconds 102 = Control valve D. Improper voltage being delivered to PC board to resynchronize software with piston position motor ran too short or disconnect power supply from PC board for...
Page 17
PROBLEM CAUSE CORRECTION 19. Err – 1007, Err – 107, A. Open up MAV/NHBP valve and check piston Err - 117 = MAV/ and seal/ stack assembly for foreign material. SEPS/NHBP/AUX A. Foreign material is lodged in Press NEXT and REGEN buttons for 3 seconds MAV valve motor MAV/NHBP valve to resynchronize software with piston position...
REPLACEMENT PARTS: FRONT COVER AND DRIVE ASSEMBLY Item No. Part No. Description Qty. CV3837-01XB TotalCare cover CV3837-01 CareSoft Pro cover CV3107-1 Motor CV3106 -1 Drive bracket & spring clip CV4050WB PC board (used on chlorine generator models) CV4062WX PC board (standard) CV3110 Drive gear, 12 x 36 CV3109...
Congratulations. You have purchased one of the fi nest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, Water-Right proudly warrants our WaterCare water ® conditioners to the original owner, at original installation location, when installed in accordance with Water-Right...
QUICK REFERENCE GUIDE: GENERAL OPERATION MANUAL REGENERATION REGEN TODAY and TIME OF DAY When the system is operating, one of six displays will be shown: NOTE: For softeners, if brine tank does will flash alternately if a regeneration not contain salt, fill with salt and wait 1.