Pioneer LISAS-B-1403 Service Manual page 122

Dc inverter split heat pumps
Table of Contents

Advertisement

Troubleshooting
For 36K~48K Units
NO. 
Malfunction 
Communication malfunction between indoor
and outdoor units. 
Open or short circuit of T1 temperature
sensor 
Open or short circuit of T2 temperature
sensor 
Open or short circuit of T2B temperature
sensor 
Indoor EEPROM malfunction 
Indoor fan speed is out of control 
Refrigerant Leakage Detection 
Outdoor unit malfunction 
Full-water malfunction 
Communication malfunction between main
10 
PCB and up-down panel PCB 
11 
Up-down panel malfunction 
12 
Up-down panel is not closed 
2.3 Outdoor unit malfunction
For YN012GMFI16RUD and YN018GMFI18RUD:
No.
Problems
1
standby for normal
2
Operation normally
3
IPM malfunction or IGBT over-strong current protection
4
Over voltage or too low voltage protection
5
Inverter compressor drive error
6
Inverter compressor drive error
Communication malfunction between compressor driver board and
7
outdoor main board
8
Compressor driver board EEPROM malfunction
120
Defrosting
lamp  
☆ 
☆ 
☆ 
☆ 
☆ 
☆ 
O (on)
X(off) ☆(flash at 5Hz) ◎(flash at 0.5Hz)
F0,F1,F2 is only available for super-slim cassette 
O(light)
X(off)
Alarm
Running lamp 
lamp  
☆ 
☆ 
☆ 
☆ 
☆ 
◎ 
☆ 
☆ 
☆ 
☆ 
☆ 
Green
Red
O
X
X
O
X
O
O
X
O
O
☆(2.5Hz flash)
Timer
Display(digital
lamp 
tube) 
E1 
☆ 
E2 
E3 
E4 
E7 
E8 
EC 
Ed 
EE 
X
F0 
F1 
O
F2 
IU display
P0
P1
P4
P4
P4
E5
Electrical Control System