2

SPECIFICATION

•Refer to the service manual OB346 when MSZ-A18YV -
MUZ-A18YV -
, MUZ-A24YV -
E1
•Refer to the service manual OB319 when MSZ-A18YV -
MXZ-A26WV -
or MXZ-A32WV -
E1
Indoor model
Function
Power supply
Capacity
Air flow(High/Med. /Low )
w
Power outlet
Running current 1
Power input 1
Auxiliary heater
Power factor 1
Fan motor current 1
Model
Winding
resistance(at 20:)
Dimensions WOHOD
Weight
Air direction
Sound level(High/Med. /Low )
w
Fan speed(High/Med. /Low )
w
Fan speed regulator
Thermistor RT11(at 25:)
Thermistor RT12(at 25:)
Thermistor RT13(at 25:)
Remote controller model
Indoor model
Function
Power supply
Capacity
w
Air flow(High/Med. /Low )
Power outlet
Running current 1
Power input 1
Auxiliary heater
Power factor 1
Fan motor current 1
Model
Winding
resistance(at 20:)
Dimensions WOHOD
Weight
Air direction
Sound level(High/Med. /Low )
w
Fan speed(High/Med. /Low )
w
Fan speed regulator
Thermistor RT11(at 25:)
Thermistor RT12(at 25:)
Thermistor RT13(at 25:)
Remote controller model
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor
Outdoor Dry-bulb temperature 35°C Wet-bulb temperature(24°C)
Heating : Indoor
Outdoor Dry-bulb temperature 7°C Wet-bulb temperature 6°C
Indoor-Outdoor piping length 5m
w Reference value
1 Measured under rated operating frequency.
OB345A
or MUZ-A26YV -
E1
as multi system units.
E1
Cooling
K /h
w
A
A
W
A(kW)
%
A
"
mm
kg
dB
w
rpm
w
k"
k"
k"
K /h
w
A
A
W
A(kW)
%
A
"
mm
kg
dB
w
w
rpm
k"
k"
k"
Dry-bulb temperature 27°C Wet-bulb temperature 19°C
Dry-bulb temperature 20°C Wet-bulb temperature 15.5°C
, MSZ-A24YV -
E1
E1
.
E1
, MSZ-A24YV -
E1
E1
MSZ-A18YV -
E1
Heating
Single phase
230V, 50Hz
w
w
852/690 /498
10
0.30
60
87
0.30
RC4V32-AA
WHT-BLK 293
BLK-RED 146
1,100O325O258
16
5
43/38 /31
w
w
w
w
1,120/940 /720
3
10
10
10
KP0A
MSZ-A26YV -
Cooling
Single phase
230V, 50Hz
w
w
1,032/798 /564
RC4V40-AA
WHT-BLK 138.2
BLK-RED 159.0
1,100O325O258
48/40 /33
w
w
1,310/1,060 /800
4
or MSZ-A26YV -
is connected with
E1
or MSZ-A26YV -
is connected with
E1
MSZ-A24YV -
Cooling
Single phase
230V, 50Hz
1,032/768 /522
w
w
10
0.34
69
87
0.34
RC4V40-AA
WHT-BLK 138.2
BLK-RED 159.0
1,100O325O258
16
5
48/40 /32
w
1,310/1030 /750
w
w
3
10
10
10
KP0A
E1
Heating
1,032/816 /564
10
0.34
69
88
0.34
16
5
w
w
1,310/1,080 /800
3
10
10
10
KP0A
E1
Heating
w
w
1,032/786 /522
w
w
w
1,310/1050 /750
w
w
w
w