STEP 3:
PREPARE THE VENTING BLOWER
ROOF VENTED INSTALLATION:
1. Remove blower unit mounting screw(s) and blower
plate screw(s). Remove the blower plate from cabinet.
See Figure 18.
2. Carefully lift the blower unit out of the microwave
oven.
3. Rotate blower unit 90° so the exhaust ports face the
top of the cabinet. See Figure 19.
4. Place blower unit back into microwave oven.
5. Use side cutters or tin snips to cut and remove
knockouts "A" from blower plate. Discard knockouts.
Be careful not to distort the plate. See Figure 20.
6. Reattach blower plate to microwave oven. Attach with
the blower unit mounting screw(s) and then the blower
plate mounting screw(s). See Figure 21.
12
blower plate
Figure 18
exhaust
ports
Figure 19
blower plate
Figure 20
blower unit
blower plate
Figure 21
blower plate
mounting
screw(s) (option)
blower unit
mounting screw(s) (option)
blower
unit
Knockouts "A"
blower plate
mounting
screw(s) (option)
blower unit
mounting screw(s) (option