D u c t i n g v e r s i o n
ATTENTION: Two persons are required for
proper installation; the unit should be installed
by a qualified operator.
Before fixing, the outlet pipe for air evacuation
to the outside must be installed.
Use an outlet pipe with:
– minimum indispensable length;
– minimum possible bends (maximum angle
of bend: 90°);
– certified material (according to the State);
– an as smooth as possible inside. It is also
advisable to avoid any drastic changes in pipe
cross-section (recommended diameter: 150
mm).
For air evacuation to the outside, follow all
the other instructions given on the "Warnings"
section.
Prepare the power supply within the telescopic
chimney (for the electrical connection, follow
all the other instructions on the "Warnings"
section).

Fixing to the wall

Draw a line on the wall in vertical line with
your hob. Mark the first 2 holes to be drilled
in the wall, respecting the distances indicated
in Fig. 4. Drill the 2 holes and fit the screw
anchors provided.
Bear in mind that the distance between the
lower edge of the hood and the hob must be
min. 650 mm.
Fix the metal bracket (A) to the wall using
the 2 holes just drilled (Fig. 4); the screws for
fixing the bracket are provided. Use the 2
cut-out triangles on the bracket to position it
exactly along the vertical axis of the hood.
Hang the hood on the bracket (Fig. 6).
Adjust the horizontal position moving the hood
to the right or left so that it is aligned with the
wall units. When adjustment has been
completed, without removing the hood, mark
the other 4 holes to be drilled (C) in the wall.
Remove the hood and drill the holes marked
(8 mm diameter). Then use the 4 screw
anchors and the 4 screws provided for final
fixing.
Mount the plate of the electrical system fixing
it with 3 screws (Fig. 7).
Install the flange in the device air outlet and
press slightly (Fig.8).
fig. 4
fig. 5
Fixing the telescopic flues
Adjust the width of the support bracket (D) of
the telescopic flue by means of the screws
(E) as shown in Fig.9; then, by means of the
screw anchors and screws (F) provided, fix
the bracket to the ceiling in such a way that
it is positioned along the axis with your hood.
Connect the air outlet pipe to the air vent of
fig. 6
the hood. - Use a flexible pipe and lock it to
the air vent of the hood with a metal hose
clamp - Fig. 10 (pipe and clamp are not
provided).
fig. 7
For exhaust hoods, turn the upper flue over
so that the air exhaust grid is in the lower
section (Fig. 11).
fig. 8
Plug in the hood.
Insert the extension flues setting them on the
hood; extend the upper flue to the ceiling
and secure with the 2 screws (H) - Fig. 12.
EN
fig. 9
fig. 10
fig. 11
fig. 12