Door Switch
NOTE
During initial startup, or anytime power is interrupted, there will
be an approximate 5 minute delay before the refrigerator starts.
During this period the controller will be assessing the tempera-
ture in the refrigerator and the display will appear erratic, this is
normal. The desired temperature set point can be programmed
during this start up period.
Starting your refrigerator
The refrigerator will begin start up when initially plugged in or
when power resumes after a power outage. At this time the re-
frigerator will take approximately 5 minutes to begin running as
noted above. If the refrigerator has been turned off during use,
"OFF" will appear on the display. To start the refrigerator from
the "OFF" position press and hold the ON/OFF button for three
seconds.
Set temperature
To set temperature set point, press and continue to hold "SET"
button. After one second, set point will be displayed. While
holding "SET" button use the "WARMER" or "COLDER" button to
desired set point.
NOTE: Momentarily pressing & releasing "SET" button will access
information menu of control. Refer to appendix A for information
on this feature.
Refrigerator operation
The available temperature range for the 6BARM refrigerator is
39° to 65°F (4° to 18°C).
It may take up to 24 hours for your refrigerator to reach desired
temperature. This will depend on amount of contents loaded
and number of openings and closings of the door.
For best results allow refrigerator to "pull down" to desired set
point before loading. Once contents are loaded, allow at least
48 hours for temperature to stabilize before making any adjust-
ments to the set point.
Alarms
Your MicroSentry™ refrigerator control will monitor refrigerator
function and alert you with a series of audible and visual alarms.
Door Ajar Alarm: If the door has been left
open for over five (5) minutes, the alarm
will sound in one (1) second intervals. The
display panel will flash "do" and the LED light will be a steady
amber color. This will stop as soon as the door is closed.
USING YOUR MicroSentry™ REFRIGERATOR CONTROL
depending upon the condition and the LED light will be a steady
amber color. "hi" indicates that the temperature is 10° F (5.5°C)
above the set point and "Lo" indicates that the temperature is
10° F (5.5°C) below the set point. The alarm will remain active
until the condition is corrected.
NOTE: During initial appliance start-up, the high temperature
alarm may sound until the interior temperature reaches set
point.
sensor alarm will sound. "E1" will flash on the display, and an
alarm will sound. Please call AGA MARVEL Customer Service or
your dealer if this error code is displayed.
sitate cleaning the air flow, "cL" will flash on the display as a
reminder. See the "Care and Cleaning" section for cleaning
instructions.
To clear the alarm:
1) Press and release the "SET button four times.
"cnd"
2) While "cnd" is displayed, press and hold the "SET" but-
ton. The display will show the number of weeks the
refrigerator has been running.
3) While holding the "SET" button, press and release the
ON/OFF button. The number shown on the display will
reset to 0.
4) Release the "SET" key.
Alarm Mute
Press any key to mute the audible portion of an alarm.
NOTE-This action will only mute the alarm. If the condition that
caused the alarm continues, the alarm code will continue to flash
and will sound for 20 seconds every 60 minutes.
High and Low Temperature Alarm: If your
unit reaches an unacceptable temperature
outside of your set point, the alarm will
sound in one (1) second intervals. The
display panel will flash either "hi" or "Lo"
Temperature Sensor Fault: If the controller
detects that the temperature sensor is
not properly functioning, a temperature
Condenser Needs Cleaning:
When the refrigerator has reached the
recommended amount of run time to neces-
will be displayed on the screen.
Control