AGA marvel 3SWCE Installation And Maintenance Instructions Manual

Refrigerated champagne and wine cellars chateau collection
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Installation
Operation
and
Maintenance
Instructions
Refrigerated Champagne
and Wine Cellars
Chateau Collection
3SWCE
6SWCE
8SWCE
3SWCCE
6OSWCE (Outdoor)
6SDZE
Note: Wine Cellars are designed exclusively for the storage of
wine. Wine Cellars cannot attain storage temperatures suitable
for fresh food storage.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3SWCE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AGA marvel 3SWCE

  • Page 1 Installation Operation Maintenance Instructions Refrigerated Champagne and Wine Cellars Chateau Collection 3SWCE 6SWCE 8SWCE 3SWCCE 6OSWCE (Outdoor) 6SDZE Note: Wine Cellars are designed exclusively for the storage of wine. Wine Cellars cannot attain storage temperatures suitable for fresh food storage.
  • Page 2: Table Of Contents

    Recommended Rough in Opening Dimensions Cleaning the cabinet............. for 3SWCE & 3SWCCE glass door......... Cleaning the interior.............. Dimensions for 3SWCE & 3SWCCE glass overlay door... Cleaning the wine shelves............ Recommended Rough in Opening Dimensions Cleaning the door gasket............for 3SWCE & 3SWCCE glass overlay door......
  • Page 3: Unpacking Your Wine Cellar

    UNPACKING YOUR WINE CELLAR Important Safety Instructions Warnings and safety instructions appearing in this guide are not meant to cover all possible conditions and situations that may If the unit was shipped or has been laying on its back for any occur.
  • Page 4: Installing Your Wine Cellar

    To ensure your side to side and front to back. The overall height of your Marvel product performs to specifications the recommended installation refrigerator may be adjusted from 33-3/4”...
  • Page 5: Electrical Connection

    ELECTRICAL CONNECTION • Do not splash or spray water from a hose on the wine cellar. Doing so may cause an electrical shock, which may result in severe injury or death. • This unit should not, under any circumstances, be installed to an un-grounded power supply.
  • Page 6: Using Your Sentry System™ Control

    USING YOUR SENTRY SYSTEM™ CONTROL Only on glass door models Status Sentry System™ Warmer Power Failure-Flashing Amber High/Low Temp-Red Light Press ON/OFF-Reset Colder Alarms OFF-Steady Amber Press and hold Figure 6 “Single Zone” Glass and Solid Door Models Status message ON OFF Door Ajar Power Failure Hi / Low Temp Upper...
  • Page 7: Sabbath Mode

    USING YOUR SENTRY SYSTEM™ CONTROL Alarms: to function for your convenience. To resume refrigeration, press and hold the “ON/OFF” keypad for 5 seconds. All Sentry control systems will alert you to conditions that could affect the storage compartment temperature. All alarm condi- Important: Although this action shuts down the refrigeration sys- tions can be silenced and re-set by momentarily pressing the tem, it does not remove power from the unit.
  • Page 8: Dimensions For 3Swce & 3Swcce Glass Door

    3” to 4” (53.82cm) (7.62 to 10.2cm) ROUGH IN OPENING DIMENSIONS, FOR 3SWCE & 3SWCCE GLASS DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required. Power outlet can be located in the back wall behind unit. Add 1”...
  • Page 9: Dimensions For 3Swce & 3Swcce Glass Overlay Door

    21-3/16” (7.62 to 10.2cm) (53.82cm) ROUGH IN OPENING DIMENSIONS FOR 3SWCE & 3SWCCE GLASS OVERLAY DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required. Power outlet can be located in the back wall behind unit. Add 1”...
  • Page 10: Dimensions For 3Swce & 3Swcce Solid Overlay Door

    3” to 4” (53.82cm) (7.62 to 10.2cm) ROUGH IN OPENING DIMENSIONS FOR 3SWCE & 3SWCCE SOLID OVERLAY DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required. Power outlet can be located in the back wall behind unit. Add 1” to depth for thickness of plug, or recess outlet 1”...
  • Page 11: Dimensions For 6Swce Glass Door

    DIMENSIONS FOR 6SWCE GLASS DOOR 47” (119.38cm) 25-21/32” (65.15cm) 26” 23-7/8” (66.04cm) (60.66cm) 24-1/16” (61.1cm) 33-3/4” to 34-3/4” (85.7 to 88.3cm) 3” to 4” 22” (7.62 to 10.2cm) (55.88cm) ROUGH IN OPENING DIMENSIONS FOR 6SWCE GLASS DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 12: Dimensions For 6Swce Glass Overlay Door

    DIMENSIONS FOR 6SWCE GLASS OVERLAY DOOR 46-25/32 (118.82cm) 23-1/32” (58.5cm) 23-7/8” 24-1/16” (60.66cm) (61.1cm) 33-3/4” to 34-3/4” (85.7 to 88.3cm) 22” *To face of door 3” to 4” (55.88cm) (7.62 to 10.2cm) without custom panel. 23-5/16”* (59.21cm) ROUGH IN OPENING DIMENSIONS FOR 6SWCE GLASS OVERLAY DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 13: Dimensions For 6Swce Solid Overlay Door

    DIMENSIONS FOR 6SWCE SOLID OVERLAY DOOR 46-27/32” (119.02cm) 23” (58.42cm) 23-7/8” 24-1/16” (60.66cm) (61.1cm) 33-3/4” to 34-3/4” (85.7 to 88.3cm) *To face of door 22” (55.88cm) without custom panel. 3” to 4” (7.62 to 10.2cm) 23-5/16”* (59.21cm) ROUGH IN OPENING DIMENSIONS FOR 6SWCE SOLID OVERLAY DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 14: Dimensions For 6Oswce Solid Door

    DIMENSIONS FOR 6OSWCE SOLID DOOR 47” (119.38cm) 25-11/16” (65.25cm) 24-1/16” 23-7/8” (61.11cm) (60.66cm) 33-3/4” to 34-3/4” (85.7 to 88.3cm) 22” 3” to 4” (55.88cm) (7.62 to 10.2cm) 26” (66.04cm) ROUGH IN OPENING DIMENSIONS FOR 6OSWCE SOLID DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 15: Dimensions For 8Swce Glass Door

    DIMENSIONS FOR 8SWCE GLASS DOOR 5231/32” (134.5cm) 3123/32” (80.6cm) 297/8” 26” (75.9cm) (66.0cm) 333/4” to 343/4” (85.7 to 88.3cm) 22” 3” to 4” (55.9cm) (7.6 to 10.2cm) 241/16” (61.1cm) ROUGH IN OPENING DIMENSIONS FOR 8SWCE GLASS DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 16: Dimensions For 8Swce Glass Overlay Door

    DIMENSIONS FOR 8SWCE GLASS OVERLAY DOOR 5221/32” (133.7cm) 291/16” (73.8cm) 297/8” 241/16” (75.9cm) (61.1cm) 333/4” to 343/4” (85.7 to 88.3cm) *To face of door 22” 3” to 4” without custom panel. (55.9cm) (7.6 to 10.2cm) 235/16”* (59.2cm) ROUGH IN OPENING DIMENSIONS FOR 8SWCE GLASS OVERLAY DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 17: Dimensions For 6Sdze Glass Door

    DIMENSIONS FOR 6SDZE GLASS DOOR 46-1/2” (118.11cm) 25-21/32” (65.15cm) 23-7/8” 25-9/16” (60.66cm) (64.92cm) 33-3/4” to 34-3/4” (85.7 to 88.3cm) 21-9/16” (54.76cm) 3” to 4” (7.62 to 10.2cm) 23-5/8” (60cm) ROUGH IN OPENING DIMENSIONS FOR 6SDZE GLASS DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 18: Dimensions For 6Sdze Glass Overlay Door

    DIMENSIONS FOR 6SDZE GLASS OVERLAY DOOR 46-1/4” (117.48cm) 23-1/32” (58.5cm) 23-19/32” 23-7/8” (59.92cm) (60.66cm) 33-3/4” to 34-3/4” (85.7 to 88.3cm) 21-9/16” 3” to 4” *To face of door (54.76cm) (7.62 to 10.2cm) without custom panel. 22-29/32”* (58.19cm) RECOMMENDED ROUGH IN OPENING FOR 6SDZE GLASS OVERLAY DOOR Electrical Requirements: A grounded 115 volt, 15 amp dedicated circuit is required.
  • Page 19: Full Overlay Panel Installation Instructions

    9/32” (7mm) Front of overlay panel Figure 9 Solid Door Models Model 14-5/8” 30-5/16” Table A 3SWCE (37.13cm) (76.99cm) Door should be Solid Door Models 23-5/8” 30-5/16” parallel to top 6SWCE (59.99cm) (76.99cm) and sides of Figure 8 refrigerator.
  • Page 20 Model Locate and mark with a pencil the location of the lock hole on 14-5/16” 30-5/16” 3SWCE the overlay panel, this is the hole in the top corner of the handle (36.35cm) (76.99cm) side of the door. Remove the clamp and remove the overlay 23-7/16”...
  • Page 21 FULL OVERLAY PANEL INSTALLATION INSTRUCTIONS 1.234” (31.3mm) .991” (25.2mm) Figure 13 Step 9: Secure overlay panel to the door. With the #10 wood screws provided fasten the overlay panel to the door. (See Figure 14). Top hinge Top hinge pin Step 10: Install lock cam (Models with locks only).
  • Page 22: Features

    Figure 17 NOT lean on or press down heavily on the wine shelves. Doing 3SWCE 4 bottles of wine per rack so may damage the shelves and the wine bottles stored on them. Pull the wine racks out gently and carefully to minimize unset- tling your wine collection.
  • Page 23: Energy Saving Tips

    ENERGY SAVING TIPS The following suggestions will minimize the cost of operating your refrigeration appliance. 1. Do not install your appliance next to a hot appliance, (cook- er, dishwasher, etc.). heating air duct, or other heat sources. 2. Install product out of direct sunlight. 3.
  • Page 24: Care And Cleaning

    The 3SWCE and 3SWCCE uses one, 6 watt light tube and the 6SWCE, 6SDZE, and 8SWCE use two, 6 watt light tubes to illumi- nate the interior of the wine cellar. The light tube is a very reli-...
  • Page 25 The 3SWCE and 3SWCCE use one 6 watt light tube in the top of the cabinet while the 6SDZE uses two, 6 watt light tubes to illu- minate the interior of the dual zone wine cellar: one in the upper compartment and one in the lower compartment.
  • Page 26: Troubleshooting Guide

    Dealer’s City • If the product is within the first year warranty period please Dealer’s State contact your dealer or call AGA MARVEL Customer Service Dealer’s Zip Code at 800.223.3900 for directions on how to obtain warranty Appliance Serial Number coverage in your area.
  • Page 27: Household Product Warranty

    Limited One Year Parts and Labor Warranty Not Supplied or Designated by AGA MARVEL AGA MARVEL warrants that it will supply all necessary parts and The above warranties also do not apply if: labor to repair or replace in the end user’s home or office, any component which proves to be defective in material or work- •...
  • Page 28 www.agamarvel.com 1260 E. VanDeinse St. Greenville MI 48838 800.223.3900 41011764-EN Rev T 12/14/12 All specifications and product designs subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products.
  • Page 29 Instructions d’installation, d’utilisation et d’entretien Caves réfrigérées à vins et champagnes Collection Château 3SWCE 6SWCE 8SWCE 3SWCCE 6OSWCE (Extérieur) 6SDZE Remarque : Les caves à vins sont conçues exclusivement pour y garder des vins. Elles ne peuvent pas atteindre des températures de conserva-...
  • Page 30 Obtention de service ..............à revêtement vitrée de 3SWCE et 3SWCCE ....... Garantie d’appareil à usage domestique ........Dimensions de porte à revêtement plein de 3SWCE et 3SWCCE . Dimensions d’ouverture brute recommandées pour porte à revêtement plein de 3SWCE et 3SWCCE ........
  • Page 31: Déballage De Votre Cave À Vins

    DÉBALLAGE DE VOTRE CAVE À VINS Importantes instructions de sécurité ATTENTION Les avertissements et les instructions de sécurité qui apparaissent dans ce guide n’ont pas la prétention de couvrir toutes les conditions et Si l’unité a été livrée étant sur le dos, ou y est restée pendant une durée situations possibles pouvant arriver.
  • Page 32: Installation De Votre Cave À Vins

    à l’autre et d’avant en arrière. La hauteur totale de votre ap- de chauffage. Pour assurer que les performances de votre produit soient pareil Marvel peut être ajustée entre 33-3/4” (85,7 cm) quand ses pieds au niveau de ses spécifications, la plage de températures recommandée de mise à...
  • Page 33: Raccordement Électrique

    RACCORDEMENT ÉLECTRIQUE ATTENTION • N’envoyez pas d’eau par éclaboussure ou par jet d’un tuyau sur la cave à vins. Cela pourrait causer une commotion électrique, entraînant potentiellement des blessures graves voire mortelles. • Cet appareil ne doit sous aucun prétexte être installé sur une alimentation électrique sans liaison de terre.
  • Page 34: Utilisation De Votre Commande Sentry System

    UTILISATION DE VOTRE COMMANDE SENTRY SYSTEM™ Uniquement sur des modèles à porte vitrée DEL de statut Sentry System™ Warmer Power Failure-Flashing Amber High/Low Temp-Red Light Press ON/OFF-Reset Colder Alarms OFF-Steady Amber Press and hold Figure 6 Modèles à “zone unique” avec porte vitrée ou pleine Message de statut...
  • Page 35 UTILISATION DE VOTRE COMMANDE SENTRY SYSTEM™ Alertes : Les éclairages d’intérieur continueront de fonctionner pour votre com- modité. Pour reprendre le refroidissement, appuyez sur le bouton “ON/ Rous les systèmes de commande Sentry vous préviennent en cas de OFF” du clavier et maintenez-le enfoncé 5 secondes. conditions qui peuvent affecter la température des compartiments d’entreposage.
  • Page 36: Dimensions De Porte Vitrée De 3Swce Et 3Swcce

    DIMENSIONS DE PORTE VITRÉE DE 3SWCE ET 3SWCCE 37” (93,98 cm) 16-9/16” (39,52 cm) 25-7/32 (64,06 cm) 14-7/8” (37,78 cm) 23-9/32 (59,13 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) 21-3/16” 3” à 4” (53,82 cm) (7,62 à 10,2 cm) DIMENSIONS BRUTES D’OUVERTURE RECOMMANDÉES...
  • Page 37: Dimensions De Porte À Revêtement Vitrée De 3Swce Et 3Swcce

    DIMENSIONS DE PORTE À REVÊTEMENT VITRÉE DE 3SWCE ET 3SWCCE 36-27/32 (93,57 cm) 13-29/32” (35,33 cm) 23-9/32” (59,13 cm) 14-7/8” (37,78 cm) 22-17/32”* (57,23 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) * Jusqu’à la face de porte sans panneau sur 3”...
  • Page 38: Dimensions De Porte À Revêtement Plein De 3Swce Et 3Swcce

    3” à 4” (53,82 cm) (7,62 à 10,2 cm) DIMENSIONS BRUTES D’OUVERTURE RECOMMANDÉES POUR PORTE À REVÊTEMENT PLEIN DE 3SWCE ET 3SWCCE ATTENTION Besoins électriques : Un circuit secteur dédié en 115 V supportant 15 A est nécessaire. La prise secteur peut être située sur la cloison murale derrière l’appareil.
  • Page 39: Dimensions De Porte Vitrée De 6Swce

    DIMENSIONS DE PORTE VITRÉE DE 6SWCE 47” (119,38 cm) 25-21/32” (65,15 cm) 26” 23-7/8” (66,04 cm) (60,66 cm) 24-1/16” (61,1 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) 3” à 4” 22” (7,62 à 10,2 cm) (55,88 cm) DIMENSIONS BRUTES D’OUVERTURE RECOMMANDÉES POUR PORTE VITRÉE DE 6SWCE ATTENTION Besoins électriques : Un circuit secteur dédié...
  • Page 40: Dimensions Pour Porte À Revêtement Vitrée De 6Swce

    DIMENSIONS DE PORTE À REVÊTEMENT VITRÉE DE 6SWCE 46-25/32 (118,82 cm) 23-1/32” (58,5 cm) 23-7/8” 24-1/16” (60,66 cm) (61,1 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) 22” * Jusqu’à la face de porte 3” à 4” (55,88 cm) (7,62 à 10,2 cm) sans panneau sur 23-5/16”* mesures...
  • Page 41: Dimensions Pour Porte À Revêtement Plein De 6Swce

    DIMENSIONS DE PORTE À REVÊTEMENT PLEIN DE 6SWCE 46-27/32” (119,02 cm) 23” (58,42 cm) 23-7/8” 24-1/16” (60,66 cm) (61,1 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) * Jusqu’à la face de porte 22” (55,88 cm) sans panneau sur 3” à 4” (7,62 à...
  • Page 42: Dimensions De Porte Pleine De 6Oswce

    DIMENSIONS DE PORTE PLEINE POUR 6OSWCE 47” (119,38 cm) 25-11/16” (65,25 cm) 24-1/16” 23-7/8” (61,11 cm) (60,66 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) 22” 3” à 4” (55,88 cm) (7,62 à 10,2 cm) 26” (66,04 cm) DIMENSIONS BRUTES D’OUVERTURE RECOMMANDÉES POUR PORTE PLEINE DE 6OSWCE ATTENTION Besoins électriques : Un circuit secteur dédié...
  • Page 43: Dimensions De Porte Vitrée De 8Swce

    DIMENSIONS DE PORTE VITRÉE DE 8SWCE 52-31/32” (134,54 cm) 31-23/32” (80,57 cm) 29-7/8” 26” (75,9 cm) (66,04 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) 22” 3” à 4” (55,88 cm) (7,62 à 10,2 cm) 24-1/16” (61,1 cm) DIMENSIONS BRUTES D’OUVERTURE RECOMMANDÉES POUR PORTE VITRÉE DE 8SWCE ATTENTION Besoins électriques : Un circuit secteur dédié...
  • Page 44: Dimensions Pour Porte À Revêtement Vitrée De 8Swce

    DIMENSIONS DE PORTE À REVÊTEMENT VITRÉE DE 8SWCE 52-21/32” (133,73 cm) 29-1/16” (73,81 cm) 29-7/8” 24-1/16” (75,9 cm) (61,1 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) * Jusqu’à la face de 22” 3” à 4” porte sans panneau (55,88 cm) (7,62 à...
  • Page 45: Dimensions De Porte Vitrée De 6Sdze

    DIMENSIONS DE PORTE VITRÉE DE 6SDZE 46-1/2” (118,11 cm) 25-21/32” (65.15cm) 23-7/8” 25-9/16” (60,66 cm) (64,92 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) 21-9/16” (54,76 cm) 3” à 4” (7,62 à 10,2 cm) 23-5/8” (60 cm) DIMENSIONS BRUTES D’OUVERTURE RECOMMANDÉES POUR PORTE VITRÉE DE 6SDZE ATTENTION Besoins électriques : Un circuit secteur dédié...
  • Page 46: Dimensions Pour Porte À Revêtement Vitrée De 6Sdze

    DIMENSIONS DE PORTE À REVÊTEMENT VITRÉE DE 6SDZE 46-1/4” (117,48 cm) 23-1/32” (58,5 cm) 23-19/32” 23-7/8” (59,92 cm) (60,66 cm) 33-3/4” à 34-3/4” (85,7 à 88,3 cm) 21-9/16” 3” à 4” * Jusqu’à la face de porte (54,76 cm) (7,62 à 10,2 cm) sans panneau sur mesures 22-29/32”*...
  • Page 47: Instructions D'installation De Panneau De Revêtement Complet

    (7 mm) Devant du panneau de revêtement Figure 9 Modèles à porte pleine Modèle 14-5/8” 30-5/16” Tableau A 3SWCE (37,13 cm) (76,99 cm) La porte doit être Modèles à porte pleine 23-5/8” 30-5/16” parallèle avec le 6SWCE (59,99 cm) (76,99 cm) haut et les côtés...
  • Page 48 Modèle Localisez et marquez avec un crayon l’emplacement du trou de verrouil- 14-5/16” 30-5/16” 3SWCE lage sur le panneau de revêtement, c’est le trou dans l’angle supérieur (36,35 cm) (76,99 cm) du côté de la poignée de la porte. Enlevez le dispositif de maintien et 23-7/16”...
  • Page 49 INSTRUCTIONS D’INSTALLATION DE PANNEAU DE REVÊTEMENT COMPLET RONDELLE D’ARRÊT DE CAME RONDELLE ÉLASTIQUE QTÉ. 1 QTÉ. 1 ÉCROU DE MAINTIEN VIS INOX QTÉ. 1 VERROU QTÉ. 1 QTÉ. 1 CAME 875 CLÉ QTÉ. 1 QTÉ. 2 VIS DE FIXATION EXTENSION 1.234”...
  • Page 50 Figure 17 le faisant vous les endommageriez, ainsi que les bouteilles posées des- 3SWCE - 4 bouteilles de vin par support sus. Tirez les supports de vin doucement avec soin, pour minimiser la perturbation de votre vin. Évitez de tirer plus d’un support à la fois pour préserver la stabilité.
  • Page 51: Conseils Pour Les Économies D'énergie

    CONSEILS POUR LES ÉCONOMIES D’ÉNERGIE Les suggestions générales suivantes vont minimiser le coût de fonctionnement de votre appareil de refroidisse- ment. N’installez pas votre appareil près d’un autre appar- eil chaud (cuisinière, lave-vaisselle, etc.), d’une con- duite d’air chaud, ou d’autres sources de chaleur. Placez l’appareil à...
  • Page 52: Entretien Et Nettoyage

    PLACER UN TUBE D’ÉCLAIRAGE. Sinon, vous risquez une commotion électrique qui peut vous blesser gravement. Les 3SWCE et 3SWCCE utilisent un tube d’éclairage de 6 Watts, et les 6SWCE, 6SDZE et 8SWCE en utilisent deux, pour éclairer à l’intérieur de la cave à vin. Ce tube d’éclairage est un composant électrique très fiable, mais si son fonctionnement était défectueux, veuillez appeler le...
  • Page 53 Votre remplacement de tube d’éclairage est terminé. 3SWCE, 3SWCCE et 6SDZE (Voir la Figure 22) : Les caves 3SWCE et 3SWCCE utilisent un tube d’éclairage de 6 Watts en Ensemble Fil de haut de l’armoire, tandis que la 6SDZE en utilise deux de cette valeur, d’éclairage...
  • Page 54 • Si le produit est encore dans sa première année de garan- État/province du revendeur tie, veuillez appeler le service à la clientèle d’AGA MARVEL au 800.223.3900 pour avoir des instructions sur la façon d’obtenir une Code Zip/postal du revendeur couverture sous garantie dans votre secteur.
  • Page 55: Garantie D'appareil À Usage Domestique

    Durant les quatre ans qui suivent l’expiration de la garantie limitée marchande, sont limitées à la durée des garanties explicites. En aucun d’un an, AGA MARVEL va fournir des pièces de remplacement pour le cas, AGA MARVEL ne sera tenue pour responsable de tous dommages système de refroidissement hermétiquement scellé...
  • Page 56 www.agamarvel.com 1260 E. VanDeinse St. Greenville MI 48838 800.223.3900 Toutes les spécifications et les conceptions des produits sont sujettes à des changements sans préavis. De 41011764-FR Rev T telles révisions ne donnent aucun droit pour l’acheteur de produits antérieurs à bénéficier de ces change- 12/14/12 ments, améliorations, ajouts, remplacements, ni de recevoir une compensation.

This manual is also suitable for:

6swce8swce6oswce3swcce6sdze

Table of Contents