MODEL MODEL MODEL KIP-30-B1/FLB-30 KIP-30-W1/FIN-30 KIP-30-W3/FIN-30-3 KIP-45-B1/FLB-45 KIP-45-W1/FIN-45 KIP-45-W3/FIN-45-3 KIP-60-B1/FLB-60 KIP-60-W1/FIN-60 KIP-60-W3/FIN-60-3 KIP-80-B1/FLB-80 KIP-80-W1/FIN-80 KIP-80-W3/FIN-80-3 KIP-30-B3/FLB-30-3 KIP-45-B3/FLB-45-3 KIP-60-B3/FLB-60-3 KIP-80-B3/FLB-80-3 CONTROLS CONTACTORS F-1T FL-402 F-2T FL-303 Importer: Almost Heaven Saunas HC66, 465-A Highway 219 North Renick, West Virginia 24966 304-497-3991 14112012...
Page 3
THE SAUNA ROOM SHALL BE PROVIDED WITH PROPER VENTILATION Figure 1. INSTALLATION OF WALL MODEL HEATER, with sensing bulb out through grommet and through CONTROL, CONTACTOR stud wall, so that capillary bulb is located 6’’ from ceiling inside Sauna room and as close to Sauna Remove heater from carton and attach heater heater as possible, taking care to avoid sharp bends to wall with screws are supplied.
Page 4
THE SAUNA ROOM SHALL BE PROVIDED WITH PROPER VENTILATION WALL-MOUNTED HEATERS-MINIMUM CLEARANCES, MIN-MAX SPACE, ADEQUATE VENTILATION Figure 3. Figure 2. Figure 3a. Figure 4. MODEL INPUT MIN. FLOOR AREA SAUNA MIN. SPACING FROM ADJACENT HEIGHT ROOM SURFACES, INCHES Min. Max. Min.
Page 6
Figure 5a. SAUNA HEATER WIRING AND HOOKUP Important! Before hooking up electrical wires to Note! If connection to heater will be made at a later junction box of heater, remove capillary tubing and time, bring flex into Sauna room 4–6” from floor, bulb from junction box and bring up wall to left and leave 3’...
Page 7
Figure 6. Use this diagram for wiring and hookup SAUNA HEATER (240 V) WITH WALL CONTROL Model Amps Voltage Phase Wire size Control Contactor KIP-30-W1, FIN-30 12.5 F-1T None KIP-45-W1, FIN-45 18.8 F-1T None KIP-60-W1, FIN-60 25.0 F-1T None SAUNA HEATER WIRING AND HOOKUP – Internal wiring only ALSO REFER TO FIGURE 1 240 V SINGLE PHASE HEATER...
Page 8
Figure 7. Use this diagram for wiring and hookup SAUNA HEATER (240 V) WITH WALL CONTROL Model Amps Voltage Phase Wire size Control Contactor KIP-80-W1 33.3 F-2T FL-402 FIN-80 SAUNA HEATER WIRING AND HOOKUP – Internal wiring only ALSO REFER TO FIGURE 1 240 V SINGLE PHASE HEATER Refer to chart above for proper wire size and KIP-30-W1 / KIP-45-W1 / KIP60-W1 / KIP-80-W1...
Page 9
Figure 8. Use this diagram for wiring and hookup SAUNA HEATER (208 V) WITH WALL CONTROL Model Amps Voltage Phase Wire size Control Contactor KIP-30-W3 F-2T FL-303 FIN-30-3 KIP-45-W3 12.5 F-2T FL-303 FIN-45-3 KIP-60-W3 16.7 F-2T FL-303 FIN-60-3 KIP-80-W3 22.2 F-2T FL-303 FIN-80-3...
Page 10
Figure 9. F-2 SAUNA CONTROL This control can be used with any heater and proper contactor. See chart for contactor model. This control can be used only with use of a time clock. This control can be used only when an attendant is on duty during hours of operation.
SAUNA – GENERAL INFORMATION NOTE! A ground fault interrupter (GFI) should not be installed in and does not belong in a Sauna. If used, Rock placement – do not operate heater without the breaker will trip, and damage could result. stones! C.
Page 12
ROOM LIGHT should be a vapor proof, wall-mounted K. LIGHT type, with rough-in box mounted flush with inside should be wall-mounted, vapor proof type, • paneling. It should mount 6’6” from floor, not located 6” from ceiling. directly over Sauna heater, and not over upper L.
Page 13
KIP-60-B1/KIP-60-B3/FLB-60/FLB-60-3 Sauna heaters type -W1, W3, -FIN without parts nr 12, 17 and 18 JH30B2401 - JH80W2083 H12/94 JF30B2401 - JFIN802083 H12/94...
MAINTENANCE INSTRUCTIONS 1. Use only clean water on Sauna stones. Do not 8. In new construction, a floor drain should also use spa or pool water as it will destroy your be provided, especially in commercial Saunas heater. for sanitary cleaning and maintenance. 2.