X-Rite Examolite TC-440B Operation Manual

Examolite and prooflite overhead luminaire

Advertisement

PLEASE READ AND FOLLOW INSTRUCTIONS—Follow all instructions before attempting installation and operation.
KEEP INSTRUCTIONS—Retain these instructions for future reference. Once you have read these instructions, keep
them available for other operators to read.
OBEY ALL WARNINGS—Please comply with all warnings and safeguards in these instructions. They have been written
to keep you and your fixture safe.
CHOOSE PROPER POWER SOURCES—Use the proper power source. If you have any doubt, consult the label on the
inside of the fixture for this information.
NOT EXPLOSION-PROOF—This fixture is not explosion-proof and should not be used in a hazardous atmosphere with
exposure to flammable substances.
TURN OFF FIXTURE BEFORE CHANGING ANY LAMPS—Always turn off the fixture before you change lamps.
Always turn off power before cleaning surfaces.
ALLOW LAMPS TO COOL BEFORE TOUCHING THEM—Do not touch the hot lamps; allow them to cool.
CLEAN PROPERLY—You can wipe the lamps and reflector with a clean, white lint-free cloth. Clean the diffuser and
housing with a dampened cloth containing a mild soap.
DO NOT OPERATE DURING LIGHTNING STORMS—As an added protection during a lightning storm, turn off the
fixture so that it will not experience electrical power surges or unnecessary power drops that could result in damage to
lamps and electrical circuitry.
SERVICE PROPERLY—With the exception of lamp replacement, do not attempt to service this product yourself. If you
should attempt unauthorized repairs, you may invalidate the warranty that is active on your fixture. For any other
malfunctions in operation, contact X-Rite Technical Service.
©2007, X-Rite, Inc.
Examolite
INTRODUCTION. The following products are described in this manual:
Examolite TC-440B is an overhead luminaire that provides blended
fluorescent daylight at 7500K. It is used for grading, sorting, and visual
quality inspections.
Examolite SD-840B is an overhead luminaire that provides simulated
fluorescent Daylight (D75, D65, or D50), llluminant A (Incandescent), and
cool white fluorescent (CWF). It is used for visual color evaluations,
metamerism testing, and in applications where products need to be
evaluated under multiple light sources.
Prooflite PLD-440 is an overhead luminaire that provides simulated
fluorescent daylight (D75, D65, or D50). It is a 4-lamp, single source fixture
typically used in viewing booth installations for visual color evaluations.
Prooflite PLD-840 is an overhead luminaire that provides simulated
fluorescent daylight (D75, D65, or D50). It is an 8 lamp, single source
fixture that provides higher levels of illumination for open room
applications. A dual source fixture can also be achieved by combining four
lamps of two different sources in one PLD-840 fixture. It is used for visual
color evaluations.

SAFETY INSTRUCTIONS

and Prooflite
®
Overhead Luminaire
OPERATION MANUAL
Part No. 17500030 Rev. B
®

Advertisement

Table of Contents
loading

Summary of Contents for X-Rite Examolite TC-440B

  • Page 1: Safety Instructions

    OPERATION MANUAL Part No. 17500030 Rev. B INTRODUCTION. The following products are described in this manual: Examolite TC-440B is an overhead luminaire that provides blended fluorescent daylight at 7500K. It is used for grading, sorting, and visual quality inspections. Examolite SD-840B is an overhead luminaire that provides simulated fluorescent Daylight (D75, D65, or D50), llluminant A (Incandescent), and cool white fluorescent (CWF).
  • Page 2: Major Components

    The reflector is constructed to provide even light distribution. The diffuser is made to control brightness and resist environmental effects. The daylight fluorescent lamps use X-Rite's patented seven phosphor technology providing the closest approximation to natural daylight in a fluorescent source.
  • Page 3: Installation Procedure

    If a windowless room is unavailable, light-tight curtains or blinds should be used. If the X-Rite fixtures are used only for lighting of a localized area, then an area with little interference from other lighting should be selected or a viewing booth or an enclosing curtain should be used.
  • Page 4 Recommendations For Location Of Fixtures There are many applications for X-Rite overhead luminaires and therefore no single installation method would be suitable for all applications. See Figure 2 and Figure 3 for the more common installation requirements. Adjustments to the dimensions may be needed to achieve the desired light level and area of view.
  • Page 5 Connection of the individual ballast input leads and incandescent socket leads must be made at the time of the installation. Series ballast circuitry is used in the X-Rite Overhead Luminaires. In order to accommodate possible installation requirements, wire entry for input power is possible from either end of the fixture.
  • Page 6: Maintenance

    Replace lamps at approximately 75 percent of their rated life expectancy to retain spectral characteristics. Replace burned out lamps immediately in order to maintain the overall performance standards of the fixture. Lamp Replacement Schedule Number of Lamp Hours Examolite TC-440B F40T12/EX 5,000 33WA19/EX 2,000 Examolite SD-840B...
  • Page 7: Specifications

    4 per fluorescent source, 8 incandescent (16 4 per source (8 Total) Number of Lamps Total) F40T12/EX fluorescent daylight lamps 33WA19/EX* X-Rite seven phosphor fluorescent daylight lamps: incandescent lamps. F40T12/75, F40T12/65, and F40T12/50 *Four metal cups for the bottom of the incandescent lamps Lamps...
  • Page 8: Spare Parts

    X-Rite, Incorporated (“X-Rite”) warrants each instrument manufactured to be free of defects in material and workmanship for a period of 12 months. This warranty shall be fulfilled by the repair or replacement, at the option of X-Rite, of any part or parts, free of charge including labor, F.O.B.
  • Page 9 This manual, as well as any revisions are the copyright of X-Rite. Any reproduction of the publication in whole or in part without the express permission of X-Rite is a breach of this copyright.
  • Page 10 Corporate Headquarters - USA 4300 44th Street SE Grand Rapids, Michigan 49512 Phone 1 800 248 9748 or 1 616 803 2100 Fax 1 800 292 4437 or 1 616 803 2705 Corporate Headquarters - Europe Althardstrasse 70 8105 Regensdorf Switzerland Phone (+41) 44 842 24 00 Fax (+41) 44 842 22 22...