Bradford White 100T399-SOLA Supplement To Installation & Operation Manual page 8

Table of Contents

Advertisement

To Decrease Temperature Setpoint:
Step 1: Depress and hold "Temperature Down" button until desired setpoint temperature appears in the display.
Step 2: Press "DONE" button for new setting to take effect immediately. If the "DONE" button is not pressed, the new
temperature setting will take effect in approximately 10 seconds.
Pressing the "NEXT" button instead of "DONE" will enter the display to show unused screens such as "Stack ----˚F,
Outdoor ----˚F, % Rate (Shows percentage of full input rate for Lightoff rate), Outlet ----˚F, Inlet ----˚F, Delta T ----˚F.
These screens are not used in our application. Press DONE to exit this screen back to the DHW setpoint
display.