This water heater, when set at a lower temperature setting is not capable of producing hot water of sufficient
temperature for sanitizing purposes.
This water heater is equipped with an energy cut out device to prevent overheating. Should overheating occur or
the gas supply fails to shut off, turn off the control panel power switch to the appliance and call a qualified service
agency.
The lower the temperature setting, the greater the energy efficiency, both to heat the water and to maintain the
storage temperature during standby periods. Lower water temperatures also extend tank life. Remember, no
water heating system will provide exact temperatures at all times. Allow a few days of operation at this setting to
determine the correct temperature setting consistent with the requirements for the installation.
The water heater temperature setting is adjusted by using the control display mounted to the control surround jacket of the
water heater. The water heater thermostat is set at the lowest setpoint of 70F (21
The control display shows the temperature setpoint in degrees Fahrenheit (
the water heater ("Standby" or "Run").
For energy efficient operation of your water heater, the suggested initial temperature setting is 120F (49
winter season, or any cold period, you may desire a higher temperature setting to adjust for the colder incoming water.
This adjustment, however, may cause additional condensation to form on the cooler tank surface. This does not mean
the tank is leaking. During summer months, the warmer incoming water temperatures will benefit the performance of your
water heater and reduce the amount of condensation developed.
Condensation does not mean your tank is leaking. Most of reported tank leaks on installation are proven to be
condensation. To avoid unnecessary inconvenience and expense, make sure the tank is leaking before calling an
independent servicing contractor or qualified service professional.
If the water heater is to remain idle for 30 days or more or is subjected to freezing temperatures while shut off, the water
heater and piping should be fully drained and the drain valve should be left fully open. Refer to the "General Operation"
section of this Installation and Operation Manual for the procedure on draining the water heater.
Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a temperature setting of 140°F
(60°C). To protect against hot water injury, install an ASSE approved mixing valve in the water system. This valve will
reduce point of discharge temperature by mixing cold and hot water in branch water lines. A licensed plumbing
professional or local plumbing authority should be consulted.
TEMPERATURE ADJUSTMENT
APPROXIMATE TIME/TEMPERATURE RELATIONSHIPS IN SCALDS
120°F (49°C)
125°F (52°C)
130°F (54°C)
135°F (57°C)
140°F (60°C)
145°F (63°C)
150°F (66°C)
155°F (68°C)
More than 5 minutes
1½ to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1½ seconds
About 1 second