Takex PB-30TK Instruction Manual

Takex PB-30TK Instruction Manual

Photoelectric beam sensor pb-30tk outdoor - 100ft (30m) / indoor - 200ft (60m) pb-60tk outdoor - 200ft (60m) / indoor - 400ft (120m) pb-100tk outdoor - 330ft (100m) / indoor - 660ft (200m)

Advertisement

Quick Links

We appreciate your purchase of our photoelectric beam sensor. This sensor will provide long and dependable service when properly
installed. Please read this Instruction Manual carefully for correct and effective use.
Please note:
This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
We are not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive surge by
lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance.
[TRANSMITTER]
COVER
[RECEIVER]
COVER
DO'S AND DONT'S
Remove all obstructions (trees, clothes
lines, etc.) between Transmitter and
Receiver.
Do not install the unit on places where it
may be splashed by dirty water or direct
sea spray.
PHOTOELECTRIC BEAM SENSOR
PB-30TK Outdoor - 100ft (30m) / Indoor - 200ft (60m)
PB-60TK Outdoor - 200ft (60m) / Indoor - 400ft (120m)
PB-100TK Outdoor - 330ft (100m) / Indoor - 660ft (200m)
INSTRUCTION MANUAL
Terminals
Operational
LED
Lens
View finder
Lens
Terminals
Alarm LED
Attenuation
LED
Lens
View finder
Lens
Avoid strong light from the sun,
automobile headlights etc. directly
shining on Transmitter / Receiver. When
strong light stays in optical axis for a long
time, it does not cause malfunction but
will affect the product life.
Do not install the unit on unsteady
surfaces.
Horizontal
adjustment
Vertical
adjustment
screw
MOUNTING PLATE
Response time
adjustment
Monitor jack
Horizontal
adjustment
Vertical
adjustment
screw
MOUNTING PLATE
The protection distance (between Transmitter / Receiver)
should be placed in the rated range.
PB-30TK : Outdoor : 100' (30m) / indoor : 200' (60m)
PB-60TK : Outdoor : 200' (60m) / indoor : 400' (120m)
PB-100TK : Outdoor : 330' (100m) / indoor : 660' (200m)
Expansion of beam
Expansion of beam can be calculated
as follows:
A=0.03 x l
Transmitter
Protection distance
[OPTION PARTS]
Pole mounting plate: 2
Pole bracket: 2
Attenuation
Tapping screw: 4
sheet: 1
l
A
66' (20m)
2' (0.6m)
135' (40m)
4' (1.2m)
200' (60m)
6' (1.8m)
330' (100m) 10' (3.0m)
Receiver

Advertisement

loading

Summary of Contents for Takex PB-30TK

  • Page 1 The protection distance (between Transmitter / Receiver) should be placed in the rated range. PB-30TK : Outdoor : 100’ (30m) / indoor : 200’ (60m) PB-60TK : Outdoor : 200’ (60m) / indoor : 400’ (120m) PB-100TK : Outdoor : 330’ (100m) / indoor : 660’ (200m) Expansion of beam •...
  • Page 2 Alarm output Tamper output (non-polarity) Dry contact relay Dry contact relay Output 1c Output N/C 30V 30V (AC/DC) 0.5A (AC/DC) 0.5A • Wiring distance PB-30TK PB-60TK, PB-100TK model Control panel voltage • wire size Example connection 3 (12VDC) AWG22 720’...
  • Page 3 Wall Mount • Supply power with cover detached. • Set Transmitter lens to Receiver lens. 1) Remove cover from The view finder is placed between 2 lenses. unit and slide the Look through view finder on either side and line-up optics mounting plate to horizontally and vertically until the opposite unit is visible.
  • Page 4 Aviary Court, Wade Road, All other warranty periods agreed are subject to a formal written agreement. Basingstoke, During the warranty period, TAKEX Europe Ltd. will repair or replace, as its sole HANTS RG24 8PE option, free of charge, any defective parts returned prepaid.