Download Print this page

Takex PB-30TK Instruction Manual page 4

Photoelectric beam sensor pb-30tk outdoor - 100ft (30m) / indoor - 200ft (60m) pb-60tk outdoor - 200ft (60m) / indoor - 400ft (120m) pb-100tk outdoor - 330ft (100m) / indoor - 660ft (200m)

Advertisement

Symptom
Possible Cause
Operation LED
1. No power supply.
does not light
2. Bad wiring connection or broken wire, short.
Alarm LED does
1. No power supply.
not light when the
2. Bad wiring connection or broken wire, short.
beam is broken
3. Beam is reflected on another object and sent into the receiver.
4. Two beams are not broken simultaneously.
5. The beam interruption time is shorter than the set response time.
Alarm LED continues 1. Beam alignment is out.
to light.
2. Shading object between Transmitter and Receiver.
3. Optics of units are soiled.
Intermittent alarms
1. Bad wiring connection.
2. Change of supply voltage.
3. Shading object between Transmitter and Receiver.
4. A large electric noise source, such as power machine, is located
nearby Transmitter and Receiver.
5. Unstable installation of Transmitter and Receiver.
6. Soiled optics of Transmitter and Receiver.
7. Improper alignment.
8. Small animals may pass through the 2 beams.
Model
PB-30TK
Detection system
Simultaneous breaking of 2 beams
Infrared beam
LED pulsed beam, Double modulation
Protection distance
Outdoor 100' (30m) or less
Indoor 200'(60m) or less
Max.beam range
Outdoor 1000' (300m) or less Outdoor 2000' (600m) or less Outdoor 3300' (1000m) or less
(Approximation)
Indoor 1000'(300m) or less
Response time
50msec.to 700msec. (Variable at pot)
Supply voltage
10V to 30VDC (Non-polarity)
Current
53mA or less
consumption
Dry contact relay output form C
Contact action:
Alarm output
Contact capacity: 30V AC/DC, 0.5A or less
Dry contact relay N/C
Tamper output
Action :
Contact capacity: 30V AC/DC, 0.5A or less
Red LED (Receiver)
Alarm LED
ON: when an alarm is initiated
Red LED (Receiver)
Attenuation LED
ON: when beam is attenuated
Functions
Monitor jack output AGC circuit, Frost proof cover
Ambient temperature -13ºF to +140ºF (-25ºC to +60ºC)
range
Mounting positions
Indoor / Outdoor
Wiring
Terminals
Weight
Transmitter: 13.3oz (380g) Receiver:14oz (400g)
Appearance
PC resin (wine red)
The specifications are subject to change without notice.
Limited Warranty
All TAKEX Products are subject to 5 years warranty.
All other warranty periods agreed are subject to a formal written agreement.
During the warranty period, TAKEX Europe Ltd. will repair or replace, as its sole
option, free of charge, any defective parts returned prepaid.
Our warranty does not cover damage or failure caused by Acts of God, abuse, misuse,
abnormal usage, faulty installation, improper maintenance, unauthorised customer
modifications or any repairs other than those carried out by TAKEX Europe Ltd.
PB-60TK
PB-100TK
Outdoor 200' (60m) or less
Outdoor 330' (100m) or less
Indoor 400'(120m) or less
Indoor 660'(200m) or less
Indoor 2000'(600m) or less
Indoor 3300'(1000m) or less
80mA or less
Interruption time + delay time
(1 to 3 sec.)
Activated when cover is detached.
Remedy
1. Turn on the power.
2. Check wiring.
1. Turn on the power supply.
2. Check wiring.
3. Remove the reflecting object or change beam direction.
4. Break two beams simultaneously.
5. Set the response time shorter.
1. Check and adjust again.
2. Remove the shading object.
3. Clean the optics with a soft cloth.
1. Check again.
2. Stabilize supply voltage.
3. Remove the shading object.
4. Change the place for installation.
5. Stabilize.
6. Clean the optics with a soft cloth.
7. Check and adjust again.
8. Set the response time longer. (Impossible in a site
where an intruder can run at full speed.)
Knockout
Grommet
Knockout
TAKEX EUROPE LTD.
Aviary Court, Wade Road,
Basingstoke,
HANTS RG24 8PE
UK
Tel. +44(0)1256-475555
Fax. +44(0)1256-466268
Email: sales@takexeurope.com
Webpage: www.takexeurope.com
PB-100TK IM-10/04 (CRI-174)

Advertisement

loading

This manual is also suitable for:

Pb-60tkPb-100tk