Takex PB-30TK Instruction Manual page 3

Photoelectric beam sensor pb-30tk outdoor - 100ft (30m) / indoor - 200ft (60m) pb-60tk outdoor - 200ft (60m) / indoor - 400ft (120m) pb-100tk outdoor - 330ft (100m) / indoor - 660ft (200m)

Advertisement

Wall Mount
1) Remove cover from
unit and slide the
mounting plate to
detach it.
2) Pull wire through on the installation site.
3) Break grommet on
mounting plate and
pull wire through it.
Secure the plate with
4mm screws.
Pull wire through sensor body (back to front) and attach it to the
mounting plate.
4) When exposed wired, break knockouts (2 positions) on the rear
of unit, pull wire through as the figure and attach it to the
mounting plate.
Wiring from
the top
Knockout
5) After wiring is completed, adjust alignment, check operation
and attach cover.
(
Note Sealing is not required for unit surround due to
rain-proof construction.
The grommet is compatible with a wire of ø0.12" (ø3mm) to
*
ø0.24" (ø6mm) outer dia. When a wire of more than ø0.24"
(ø6mm) outer dia. is used, cut off the dotted line portion on the
below figure by pliers or the like. Then make corking to prevent
insects from entering into the unit.
Adjust response time as follows. The unit does not detect the passing object faster than the response time set. If the response time is set longer, the
unit does not detect human beings. Adjust to a little longer response time in a site where large passing objects, such as birds, newspaper or carton
box may move.
Response time (sec.)
(0.3)
0.7
0.05 (standard)
Grommet
Wiring from
the bottom
Knockout
)
Grommet
Response 0.05 sec.
Run at full speed
Supply power with cover detached.
Set Transmitter lens to Receiver lens.
The view finder is placed between 2 lenses.
Look through view finder on either side and line-up optics
horizontally and vertically until the opposite unit is visible.
(Hold the mental portion and change horizontal angle.)
View finder
Vertical adjustment screw
Clockwise: Upward
Counterclockwise: Downward
Further, fine tune until receiver attenuation LED is OFF.
When the unit is used outdoors, a tester is advisable to be used for
adjustment. You can confirm the beam level by inserting a tester in
monitor jack of Receiver.
The reference follows:
Monitor output voltage
Alignment (outdoor)
700mV or more
Best
250mV to 700mV
Good
60mV to 250mV
Re-adjustment
Less than 60mV
Note: The above voltage shows attenuation sheet condition.
Alarm Led
Attenuation LED
Tester
Receiver
(Testing)
Units should be tested on a regular monthly basis. To
test, walk in front of Receiver and watch to see if the
walk test LED lights as the beam is blocked. Relay
function should be confirmed by watching status light
on control panel.
(Maintenance) Our photoelectric beams are virtually maintenance free,
with the exception of units that are located in dusty or
dirty environments. Dirty units should be cleaned off
with a damp cloth as necessary.
Response 0.3 sec.
Walk with quick steps
View finder
Horizontal
adjustment
Alignment (indoor)
Best
Good
Re-adjustment
Attenuation sheet
For outdoor use, adjust with
attenuation sheet on until
attenuation LED is OFF.
After adjustment, take out
attenuation sheet.
Response 0.7 sec.
Walking