POINTS OF INSTALLATION
Heights of installation
Install the sensor at a height of 31" to 39" (80 to
100cm) to catch human pattern.
Position of installation
Using the adjustments, the lens can move
horizontally ( ±90 degrees) and vertically (±10
degrees) allowing the unit to work in all directions.
( example 1 to 3)
±10˚
Vertical
adjustment
screw
±90˚
Terminal configuration
[Transmitter]
Power
10V to 30VDC (non-polarity)
[Receiver]
Alarm
Power
COM
10V to 30VDC
Alarm output
(non-polarity)
Dry contact relay
Output 1c
30V (AC/DC) 0.5A
Wiring distance
PB-30TK
model
12V
voltage
wire size
AWG22
720'
(Dia 0.65mm)
(220m)
AWG20
1200'
(Dia 0.8mm)
(366m)
AWG18
1800'
(Dia 1.0mm)
(549m)
AWG17
2200'
(Dia 1.1mm)
(670m)
Note 1) Maximum wiring distance when two or more sets are connected
is the value above divided by the number of sets.
2) The signal line can be wired to a distance of up to 3,300 ft.
(1,000m) with AWG22 (dia 0.65mm) telephone wire.
Exemple 1
Horizontal
adjustment
NC
NC
When cover
attached
NO
Tamper output
Dry contact relay
Output N/C 30V
(AC/DC) 0.5A
PB-60TK, PB-100TK
24V
12V
24V
6200'
490'
4200'
(1890m)
(150m)
(1280m)
10500'
830'
7200'
(3200m)
(250m)
(2200m)
16000'
1200'
10500'
(4880m)
(366m)
(3200m)
20000'
1450'
13500'
(6000m)
(442m)
(4000m)
CAUTIONS ON INSTALLATION
Avoid overhead wiring
When installing indoors, wiring procedures
similar to those for telephones or intercoms are
acceptable.
Outdoor wires should be placed inside pipes, or
31" to 39"
underground cable / metal shielded cable should
(80 to 100cm)
be used.
Exemple 2
Connection
Example connection 1
Transmitter
Example connection 2
TR.
Example connection 3
TR.
Exemple 3
Receiver
RE.
TR.
RE.
RE.
TR.
RE.
Control panel
(12VDC)
Power
Alarm
signal
Control panel
(12VDC)
Power
Alarm
signal
Control panel
(12VDC)
Power
Alarm (1ch.)
Alarm (2ch.)