We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly
installed. Please read this Instruction Manual carefully for correct and effective use.
Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive
surge by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance.
This product is a passive sensor that can be used both indoors and outdoors, and that detects the far infrared radiation given off by body heat.
Using this sensor with other products enables a variety of applications, such as giving notifications of visitors or waring in the detection of intruders.
(1) Dual Zone system
which initiates an alarm only when detection occurs in
both the horizontal and downward zones simultaneously.
This prevents false alarms for distant automobiles or for
small animals.
that do not enter the downwards zone are not detected.
Small animals that do not enter the horizontal zone are
not detected. Similarly, birds and other objects that only
enter the horizontal zone are also not detected.
Detected
Detection range
(2) Selection of area corresponding to intended
purpose
wide, 180° angle, meaning
that a single unit can
cover a wide range.
Approximately 180°
masking of zones for which detection is not required.
Dual Zone Outdoor PIR
OMS-12FE
Instruction Manual

Main Features

Horizontal zone
Not detected
[3 DETECTION AREA]
(3) Rainproof housing
IEC standard: IP54 compliant.
(4) Back Tamper
Use of the provided back tamper rubber enables detection of
interference with the sensor, such as attempts to remove it
from the mounting surface.
(5) Support for mounting on poles
(optional pole attachment)
Use of the optional pole attachment enables mounting on
poles with a diameter of 1.49" to 1.77" (38mm to 45mm).
1.49" to 1.77"
(38mm to 45mm)
[4 FUNCTION]
[7 INSTALLATION]

Advertisement

Table of Contents
loading

Summary of Contents for Takex OMS-12FE

  • Page 1: Main Features

    OMS-12FE Instruction Manual We appreciate your purchase of a TAKEX passive infrared sensor. This sensor will provide long and dependable service when properly installed. Please read this Instruction Manual carefully for correct and effective use. Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
  • Page 2: Parts Description

    PARTS DESCRIPTION Please confirm that the sensor and all parts are included in the packaging. Pole mounting bracket knockout Wall mounting knockout PARTS Accessory (use for pole mounting option) [7-2 Installation Method] [7-2 Installation Method] Wiring hole [6 WIRING] Terminal Instruction Manual [6 WIRING] Adjustment index...
  • Page 3 Caution Mount the sensor so that when viewed from the front, the Do not install in an horizontal zone is parallel to the ground. Additionally, environment subject to ensure that the sensor is not at an angle when viewed electrical noise or intense from the side.
  • Page 4: Detection Area

    DETECTION AREA <Detection area after adjustment of detection distance> Detection Area Please refer to 3-2 Area Adjustment. <Default detection area> [SIDE VIEW] 3.3' (1m) 40'(12m) 16.5' (5m) (10m) (12m) 33'(10m) 3.3' (1m) 16.5' (5m) (10m) (12m) 16.5'(5m) 3.3' (1m) DETECTION DISTANCE 16.5' [TOP VIEW] (5m)
  • Page 5 (by DIP switches and , it is possible to disable 90° ranges to the left or right) The default is a 180° detection area. Regardless of the settings of DIP switch , if DIP switch is OFF, then the sensor will cover a 180° detection area. [5 SETTING] To activate only the left area To activate only the right area...
  • Page 6 FUNCTION WARM UP After turning the power ON, the operation LED will blink for approximately 1 minute. During this time, the device is stabilizing, and will not operate. OPERATION LED (RED) LED (only for sensor detection) can be disabled by the settings switch. Wake-up : blinking (approx.
  • Page 7: Sensitivity Adjustment

    SETTING SENSITIVITY ADJUSTMENT The sensor can be adjusted in accordance with the environment and intended purpose. Normally, use medium (100%). Setting the sensitivity to 170% will trigger detection even at small changes in temperature. Use this in stable environments. Setting the sensitivity to 30% will not trigger detection unless there is a large change in temperature.
  • Page 8: Terminal Configuration

    WIRING Terminal Configuration Wiring Insertion For embedded wiring Tamper Power Alarm Position the back of the sensor so that the wiring box is aligned with the wiring from the wall, then feed the wiring through the wiring hole and connect to the terminals. Supply Voltage Wiring 9V to 28VDC (non polarity)
  • Page 9: Installation

    INSTALLATION Select a mounting location that matches the intended purpose. For pole mounting [2 PRECAUTIONS] Using the pole attachment : BP-32 (Sold Separately) [3 DETECTION AREA] [Supported pole diameter of 1.50" to 1.77" (38mm to 45mm)] Removing the Cover (1) Remove the pole mounting bracket knockouts (4 locations). (1) Loosen the cover locking screws, and remove the cover.
  • Page 10: Troubleshooting

    TROUBLESHOOTING Solve possible problems according to the following table. If normal operations cannot be restored by this means, contact either the dealer from whom you bought the unit or TAKEX. Trouble Check Corrective Action (1) The power supply is not connected...