Samsung AQ24A1QE Service Manual page 22

Room air conditioner
Hide thumbs Also See for AQ24A1QE:
Table of Contents

Advertisement

Operating Instructions and Installation
3-2-2(i) Refrigerant Adjustment
Class
Connection
Air-Purge
Pipe Length
Method
Refer to the
5m Max.
detailed Air-Purge
Procedure
5~10m
3-2-2(j) Flare unt fixing torque
Outter diameter
ø 6.35 mm
(Liquid Side)
ø 9.52 mm
(Gas Side)
ø 12.7 mm
(Gas Side)
ø 15.8 mm
(Gas Side)
3-12
At installation
Refrigerant
Adjustment
Unnecessary
Add "A" of refrigerant
(R-22) for every 1m.
Fixing Torque
160
300
500
700
At service
Air-Purge
Method
Purge air using a
vaccum pump
or an additional
refrigerant cylinder.
MODEL
AQ24A1QE
AQ24B1QE
AQ18A1QE
AQ18B1QE
Torque (kg-cm)
Final Torque
200
350
550
750
Samsung Electronics
Refrigerant
Quantity
refer to
specification sheet
Add "A" of refrigerant
(R-22) for every 1m.
"A"
30g
20g