1.1 General Description

The ProCon IP Control Unit allows you to connect your RS232 controlled products to an IP infrastructure and
control them from a single point using the ProCon Site Manager® software.
There are five variants of the ProCon IP Control Unit available, all of which have the following features. See
table 1.1 for a comparison chart of the differences between the variants.
DHCP or manually configured IP address, subnet mask & default gateway.
Built in e-mail server so alerts are sent even when Site Manager® software is not running.
2 available e-mail addresses for multiple alerting.
Closed loop that can trigger an e-mail alert when the loop is broken, allows hardware to act as a
security measure for expensive audio visual equipment.
2 built in timers that can trigger alerts for measuring usage, i.e. e-mail gets sent when the filter on a
projector needs changing.
Projector lamp expiration alert (uses one of the timers), sends an e-mail to notify that a projector
lamp has passed a preset duration and needs changing (requires Site Manager® software to be
running)
Infra red port for controlling non-RS232 devices such as VCR's and DVD players.
Built in scheduling that operates from the onboard clock allowing events to occur without Site
Manager® software.
Number of RS232 ports
Loop through port
Power extension port
Battery backed rtc
RS232 Interface
Closed loop interface
IR Interface

1.2 Electrical Specifications

Supply voltage
Supply current (@12V)
Power supply included
Current drawn with
8416-03 ProCon
Control Panel attached
to power loop through.
Operating temperature
Table 1.2 Electrical specifications of the IP Control Unit variants
Tel: +44 (0)1442 242 224
E-Mail: technical@procon.co.uk
1. Introduction to the IP Control Unit
8450-02
8455-02
3
1
x
x
x
x
13 pin phoenix
D9 male
13 pin phoenix
2 pin phoenix
13 pin phoenix
3.5mm jack
Table 1.1 Comparison of the IP Control Unit variants
8450-02
8455-02
12V
12V
250mA
300mA
12V 500mA
12V 500mA
375mA
375mA
0° - 70° F
0° - 70° F
- 2 -
8460-02
8465-02
3
1
x
x
13 pin phoenix
D9 male
13 pin phoenix
2 pin phoenix
13 pin phoenix
3.5mm jack
8460-02
8465-02
12V
12V
250mA
300mA
12V 500mA
12V 500mA
425mA
425mA
0° - 70° F
0° - 70° F
www.procon.co.uk
8701-03
2
x
x
3 pin phoenix
2 pin phoenix
x
8701-03
mains
X
X
X
0° - 70° F

Advertisement

Table of Contents
loading

Related Products for Procon 8450-02

This manual is also suitable for:

8455-028465-028460-028701