8460-02 (3 port version with real-time clock)
8465-02 (1 port version with real-time clock)
8701 control system with IP interface
Tel: +44 (0)1442 242 224
E-Mail: technical@procon.co.uk
IP Control Units
8450-02 (3 port version)
8455-02 (1 port version)
Installation Guide
www.procon.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8450-02 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Procon 8450-02

  • Page 1 IP Control Units 8450-02 (3 port version) 8455-02 (1 port version) 8460-02 (3 port version with real-time clock) 8465-02 (1 port version with real-time clock) 8701 control system with IP interface Installation Guide Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk...
  • Page 2: Table Of Contents

    IP Control Unit Installation Guide Revision 1.0 Dated 20 June 2005 Contents 1. Introduction to the ProCon IP Control Unit ....................2 1.1 General Description..........................2 1.2 Electrical Specifications..........................2 2. Getting Started ............................... 3 2.1 Physical Connections ..........................3 2.2 Using the loop through facility ........................
  • Page 3: Introduction To The Procon Ip Control Unit

    ProCon Site Manager® software. There are five variants of the ProCon IP Control Unit available, all of which have the following features. See table 1.1 for a comparison chart of the differences between the variants.
  • Page 4: Getting Started

    Figure 2.2 shows the RS232 side of the Control Unit and connections to the power loop through, Infra red (IR) and closed loop, details of the connections are described in tables 2.2 / 2.3. Figure 2.2 Interconnect side of the IP Control Unit (8450-02 / 8460-02) Item...
  • Page 5: Using The Loop Through Facility

    2.2 Using the loop through facility The 8450-02 / 8460-02 have dual loop through facility available allowing the IP Control Unit to sit in the middle of an existing connection between devices. Any RS232 received on the RX of port 1 sent straight out of the TX of port 3 and likewise anything received on the loop port gets sent out of port 2.
  • Page 6: Connecting The Control Unit Via A Crossover Cable

    Select - Local Area Connection Right Click and Select - Properties. Click - Internet Protocol (TCP/IP) Select - Properties Select the first option - Obtain An IP Address Automatically Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 5 -...
  • Page 7 As there is no DHCP server present in the connection, the IP Control Unit will also have assigned itself a 169.254.x.x address. Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 6 -...
  • Page 8 The IP Control Unit is now ready for use symbolised by the green ticks. For more information on using the Site Manager® software please refer to the instruction manual. Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 7 -...
  • Page 9: Connecting The Control Unit To A Network With A Dhcp Server

    The IP device will be present in the list. Double Click the Control Unit Click - Done The IP Control Unit is now ready for use symbolised by the green ticks. Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 8 -...
  • Page 10: Connecting The Control Unit Using A Static Ip Address (Single Subnet Network)

    The second method is probably the easier of the two as the address only needs to be entered once hence eliminating the possibility of conflicting settings being entered. Although the first can be performed over the network. Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 9 -...
  • Page 11: Connecting To A Network With Multiple Subnets

    Click – Add The software will then attempt to connect to the Control Unit and assuming that all the network routes are correct a green tick will appear besides the unit. Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 10 -...
  • Page 12: Appendix A - Troubleshooting

    The link light’s colour signifies the connection speed, a 100Mbs full duplex connection will show as • green whilst a 10Mbs connection or a half duplex connection will show as red. Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 11 -...
  • Page 13: Appendix B - Revision History

    IP Control Unit Installation Guide Revision 1.0 Dated 20 June 2005 Appendix B – Revision History Date Revision Notes 20.06.05 First release Tel: +44 (0)1442 242 224 www.procon.co.uk E-Mail: technical@procon.co.uk - 12 -...