Description of "I FEEL..." mode
Details of operation
According to the room temperature when the operation starts, the opera-
tion mode is automatically set to COOL, DRY or HEAT. However, when
operation is started again within 2 hours after it is stopped, the same
operation mode before the operation is stopped is selected. The opera-
tion mode selected first is not changed even if the room temperature
changes. If the operation mode does not match the room condition, se-
lect the appropriate operation mode by pressing the
Details of auto operation
Room temperature
Operation mode
when started
About 77 °F or higher
COOL
About 77 °F - 73 °F
DRY
About 73 °F or lower
HEAT
NOTE
COOL: When the room temperature is 4
since the air conditioner is operating to reach the target (set) temperature. In this case, please wait until
the room temperature drops to within 4
HEAT: When the room temperature is 4
changed since the air conditioner is operating to reach the target (set) temperature. In this case,
please wait until the room temperature rises to within 4
set temperature.
Details of display on the indoor unit
The operation indicator at the right side of the indoor unit indicates
the operation state.
Lighted
Operation Indicator
Not lighted
Operation indicator lamp
Indication
This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.
This shows that the room temperature is approaching the
target temperature.
Description of "AUTO RESTART FUNCTION"
■ This unit is equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main power.
■ If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.
■ If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.
■ If the unit is operated in "I FEEL ..." mode before power failure, the operation is not stored in the memory. In "I FEEL ..."
mode, the operation is decided by the initial room temperature at (re)start.
■ Since the air conditioner has been shipped from the factory with the COOL mode saved in the memory for auto restart
function, it starts cooling operation when the user turns on the main power for the first time after installation.
MODE
button.
Target temperature
(initial state)
About 75 °F
About 79 °F
°
F higher than the set temperature, the set temperature may not be changed
°
F of the set temperature and then change the set temperature.
°
F lower than the set temperature, the set temperature may not be
°
F of the set temperature and then change the
Operation state
Room temperature:
About 77 °F or higher
→ COOL
About 77 °F - 73 °F→ DRY
About 73 °F or lower
→ HEAT
Difference between target
temperature and room temperature
About 4 °F or more
About 4 °F or less
7