Fig. 3
90°
80°
70°
60°
50°
West
S.W.
less than optimum by
8
Potterton Solar - Solar Thermal Domestic Hot Water System
North
Angle of tilt
90°
80°
70°
60°
50°
40°
40°
30°
30°
20°
20°
10°
10°
S.E.
South
0-5%
5-10%
2.0
Collector panels must be connected in series.The
connections are 1" BSP female union connections.
All connecting pipe work and fittings must be of a
suitable metal; either copper, brass or stainless steel.
Soft soldered joints must not be used.Any seals or sealing
compounds must be resistant to temperatures of up to
150°C and be resistant up to a 50% glycol/water mix.
Connections
When tightening the connections, always apply
counter-pressure with a wrench or another spanner
to prevent damage to the absorber.
East
Collector inclination
The collector is suitable for angles between 15°
(minimum) and 75° (maximum).
The roof aspect should ideally face South, however
orientations between 30° East and 40°West of South are
acceptable. Fig.3 shows the efficiency loss for varying
angles of inclinations and roof orientation.
Solar fluid
The Potterton Solar collector panels MUST be
protected with a water/glycol heat transfer fluid. Use only
the fluid supplied with the system which is supplied pre-
mixed to a concentration of 40% glycol / 60% water.Top
10-20%
ups can be made with water but the glycol concentration
must not be allowed to fall below 30% or inadequate frost
protection will be given. Systems found to have lower
glycol concentrations will not be covered by the warranty.
2.3
A. Installation batten
30x40x2450
B. Attachment brackets
C. Self tapping screws 5x60
D. Connection bend
E. Flat gasket
F. Lower flashing (left and right LH & RH
hand corner and extension)
Note: Flashing for slate and flat tile roofs does not
have corrugated lead skirt
G. Left and right hand side
flashing
H. Left and right hand side
cover strips
I. Sealed plumbing screws
4.5x35
J. Middle cover strip
K. Sealed plumbing screws
3.9x13
L. Wooden support board
and wedges
M. Self tapping screws 6x120
N. Upper flashing (left and right
hand corner and extension)
O. Metal retainers and
roofing nails
P. Foam sealing strip
(1m lengths)
Installation of solar collector
Mounting kit parts list.
1 panel
1
(cut in half)
4
16
Not required
2
corner
2
2
8
Not required
3
1
8
LH & RH
corner
10
Cut to suit
2 panels
2
5
20
1
2
LH & RH
corner & ext.
2
2
9
1
5
1
8
LH & RH
corner & ext.
12
Cut to suit

Advertisement