In Roof mounting
22: If fitting two or more collectors, position the upper
middle section onto the collector ensuring it overlaps
the upper left hand section previously fitted. Secure
using self tapping screw 4.5x35mm. Screw must be
positioned outside the re-inforcing seam.
23: Position the upper right hand corner onto the
collector. Ensure it overlaps either the upper left
hand corner section or upper middle section.
24: Secure the upper right and left hand corner sections
to the collector using sealed plumbing screws
4.5x35mm.
25: Secure the sides of the upper left and right hand
corner sections to the roof batten using metal
retainers and roofing nails.