2) Disassembly of the Noise Filter,
Noise Filter and Power Cord(Figure A)
Disconnect 2 connector in Noise Filter and
Disassemble Noise Filter and Power Cord.
Inlet Valve (Figure B)
Disconnect the leads from the inlet valve and remove
three screws.
Remove the hoses and output pipes from the input
valve.
Remove the inlet valve.
Pressure Switch (Figure C)
Disconnect the leads from pressure switch and
disassemble pressure switch
Disconnect pressure tube from the pressure switch .
DT Housing (Figure D)
Remove the hoses and output pipes from the input
valve.
Disassemble the connector pipe and the DT housing.
26
Power Cord, Inlet Valve, Pressure
Switch, and DT Housing.