SEFRAM 3515 User Manual page 58

600a & 1000a power clamps
Table of Contents

Advertisement

Available languages

Available languages

(3) Peak Hold : Peak MAX / Peak MIN
3515,3525
Function
Range
140.0V
ACV
1400V
140.0A
ACA
850A
Function
Range
140.0V
ACV
1400V
140.0A
ACA
1400A
Overload protection : 1000 V
600 A
for 3515,3525
rms
1000 A
for 3535
rms
Accuracy defined for :
Sine wave, ACV>5Vrms / ACA≧5Arms, Freq.50~400Hz.
- Only suitable for the repetitive events.
(4) Frequency
3515,3525,3535
Function
Range
20.00 ~ 99.99Hz
Frequency
20.0 ~ 999.9Hz
0.020 ~ 9.999KHz
Overload protection : 1000 V
600 A
for 3515,3525
rms
1000 A
for 3535
rms
Sensitivity :
10~100Vrms for AC 100V range
10~100Arms for AC 100A range ( >400Hz Unspecified)
100~1000Vrms for AC 1000V range
100~600/1000Arms for AC 600A/1000A range
( >400Hz Unspecified)
- Reading will be 0.0 for signals below 10.0 Hz.
Accuracy
± (3.0% + 15dgt)
± (3.0% + 15dgt)
3535
Accuracy
± (3.0% + 15dgt)
± (3.0% + 15dgt)
rms
Accuracy
± (0.5% + 3dgt)
rms
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

35253535

Table of Contents